MYP Physics · topic MYP-13.06

Non-ohmic components and sensors

Connect the ideas, make your working visible, and test the result. Use the hints when you need a starting point; open the full solution after your attempt.

Extra challenging questions

Work through the linked stages and explain what each result means.

Extra challenging · 01

A thermistor alarm with a reversed response

Optional enrichment: this challenge may extend beyond the usual syllabus depth and assumes confidence with algebra and graph interpretation. A 6.0 V supply is connected to a 2.0 kΩ fixed resistor in series with an NTC thermistor. Output voltage is measured across the thermistor by a high-resistance input. Its resistance–temperature data are supplied. The alarm activates when output falls below 2.0 V. Supplied data (Temperature / °C; Resistance / kΩ): (10, 8), (20, 4), (30, 2), (40, 1), (50, 0.5). (a) Find output voltage at 20°C and 40°C, and identify the temperature at which the threshold is reached. [3 marks] (b) Predict how the response changes if output is taken across the fixed resistor, and explain why the thermistor is not an ohmic resistor with one universal resistance. [3 marks]

Explore the question data

Thermistor calibration

Supplied question data. Read the labelled axes and use the observations to test the physical model.

Vertical axis (y): Resistance / kΩ

Thermistor calibrationSupplied question data. Read the labelled axes and use the observations to test the physical model. Horizontal axis: Temperature / °C. Vertical axis: Resistance / kΩ. Exact values are available in the data table below.02468012.52537.550xy

Horizontal axis (x): Temperature / °C

Reading 1Temperature / °C: 10Resistance / kΩ: 8
Read the exact data as a table
Thermistor calibration — supplied values
Temperature / °CResistance / kΩ
108
204
302
401
500.5

These are the supplied values, not a worked answer. No fitted trend is drawn.

Show a hint

Begin with part (a): Find output voltage at 20°C and 40°C, and identify the temperature at which the threshold is reached.

Reveal the worked solution
  1. For a series divider, Vout = 6.0 Rtherm/(2.0 kΩ+Rtherm). At 20°C, this is 6(4)/(2+4) = 4.0 V.
  2. At 40°C, Vout = 6(1)/(2+1) = 2.0 V. The NTC resistance decreases as temperature rises, so the thermistor voltage also decreases.
  3. The strict 'below 2.0 V' trigger occurs above 40°C, assuming monotonic response and negligible self-heating. A real alarm needs tolerance and hysteresis specifications.
  4. The two divider voltages sum to 6.0 V, so the fixed-resistor voltage is 6.0−Vtherm.
  5. As the thermistor resistance falls, total resistance falls and current rises; the fixed-resistor voltage IRfixed therefore rises.
  6. Resistance depends strongly on temperature. Even at one bath temperature a large measuring current can cause self-heating, so a calibration requires controlled conditions and suitably low power.

Answer (a) Vout = 4.0 V at 20°C and 2.0 V at 40°C; it activates above 40°C in this ideal calibration. (b) The fixed-resistor output rises with temperature; it is 2.0 V at 20°C and 4.0 V at 40°C.

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.

Open full question workspace and marking guide →