Skip to main content
Course and syllabus guidance

University Physics III · unit UPIII-07

Thermodynamics

Connect the ideas, make your working visible, and test the result. Use the hints when you need a starting point; open the full solution after your attempt.

Extra challenging questions

A selection from this pathway. Open a topic below for its complete practice and challenge set.

Extra challenging · 01

Thermodynamic systems and the first law: infer an input with uncertainty

The first law states that the internal energy of a closed system changes only by the heat that enters it minus the work it does on its surroundings, ΔU = Q − W, whatever path connects the two equilibrium end states. Use the supplied topic model Y_out = (q-w)/(1.5*n*8.314), where Y_out is ΔT, monatomic ideal gas (K). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793. n is Argon in the system n, measured in mol. Keep q (Heat into the system Q) = 400 J; w (Work done by the system W) = 150 J fixed. For this exercise use only 0.978125 mol ≤ n ≤ 4.52187 mol on this continuous branch. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. A reading gives Y_out = 6.3846194 K, with a bounded reading uncertainty ±0.29271 K. Treat the model and all fixed inputs as exact for this exercise; the bound is not a standard deviation. First estimate the unknown n by straight-line interpolation between the two endpoint predictions. Then solve the actual model on the stated branch to an absolute input tolerance of 0.000354375 mol, using a numerical bracket if required. Find the full input interval consistent with the bounded reading uncertainty and compare it with a symmetric input-error assumption. Do not assume that the supplied calibration points prove monotonicity outside this branch.

Explore the question data

ΔT, monatomic ideal gas against n

Predictions from the supplied Thermodynamic systems and the first law model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.

Vertical axis (y): ΔT, monatomic ideal gas / K

ΔT, monatomic ideal gas against nPredictions from the supplied Thermodynamic systems and the first law model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law. Horizontal axis: n: Argon in the system n / mol. Vertical axis: ΔT, monatomic ideal gas / K. Exact values are available in the data table below.3.7918.12712.4616.821.140.83641.7932.753.7074.664xy

Horizontal axis (x): n: Argon in the system n / mol

Axes show the supplied calibration interval; the origin may lie outside the plot.

Reading 1n: Argon in the system n / mol: 0.9781ΔT, monatomic ideal gas / K: 20.49
Read the exact data as a table
ΔT, monatomic ideal gas against n — supplied values
n: Argon in the system n / molΔT, monatomic ideal gas / K
0.978124999999999920.49483235611411
1.864062499999999710.754203734222491
2.757.289639235754222
3.63593755.513435777794341
4.5218754.433229113658408

These are the supplied values, not a worked answer. No fitted trend is drawn.

Show a hint

The model's endpoint predictions bracket the reading. Solve Y_out(n) = Y_measured and then solve again at Y_measured − u and Y_measured + u; a nonlinear inverse can give unequal input deviations.

Reveal the worked solution
  1. Endpoint predictions are Y_out(0.978125) = 20.4948 K and Y_out(4.52187) = 4.43323 K. The target lies between them. On the selected branch the response is strictly decreasing.
  2. Endpoint interpolation gives n_line = 0.978125 + (6.38462 − 20.4948)(4.52187 − 0.978125)/(4.43323 − 20.4948) = 4.09133 mol. This estimates the inverse of the endpoint chord, rather than assuming that chord is the physical model.
  3. Use the actual equation, not the chord, and bracket its root. Evaluating the midpoint and retaining the sign-changing half-interval gives n = 3.13981 mol; substituting back gives Y_out = 6.3846194 K.
  4. The interpolation error in the input is |n_line − n| = 0.951518 mol. This is larger than the requested numerical tolerance.
  5. Invert both limits Y_out = 6.0919094 K and 6.6773294 K. Sort the roots even if the response decreases: 3.00217 mol ≤ n ≤ 3.29068 mol.
  6. The lower and upper input deviations are 0.137638 mol and 0.150865 mol. They differ because the inverse response is nonlinear; a symmetric error bar would only be a local approximation. This interval includes reading uncertainty only, not model error or uncertainty in fixed inputs.

Answer n ≈ 3.13981 mol; compatible interval [3.00217, 3.29068] mol. Endpoint interpolation gives 4.09133 mol.

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.

Extra challenging · 02

Gas work, p-V paths, and path dependence: infer an input with uncertainty

The work done by a gas in a quasi-static process is W = ∫p dV along its path in the p-V plane: the signed area under the curve, positive for expansion, negative for compression, and different for different paths between the same two states. Use the supplied topic model Y_out = 100*p1*(1-1/v2), where Y_out is W ROUTE B (V₁ THEN p₂) (J). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793. v2 is Final volume V₂ (V₁ = 1.0 L), measured in L. Keep p1 (Initial pressure p₁) = 2 × 10⁵ Pa; f (External pressure p_ext / p₂) = 0.6 fixed. For this exercise use only 1.76563 L ≤ v2 ≤ 3.73438 L on this continuous branch. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. A reading gives Y_out = 132.5819 J, with a bounded reading uncertainty ±2.0792 J. Treat the model and all fixed inputs as exact for this exercise; the bound is not a standard deviation. First estimate the unknown v2 by straight-line interpolation between the two endpoint predictions. Then solve the actual model on the stated branch to an absolute input tolerance of 0.000196875 L, using a numerical bracket if required. Find the full input interval consistent with the bounded reading uncertainty and compare it with a symmetric input-error assumption. Do not assume that the supplied calibration points prove monotonicity outside this branch.

Explore the question data

W ROUTE B (V₁ THEN p₂) against v2

Predictions from the supplied Gas work, p-V paths, and path dependence model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.

Vertical axis (y): W ROUTE B (V₁ THEN p₂) / J

W ROUTE B (V₁ THEN p₂) against v2Predictions from the supplied Gas work, p-V paths, and path dependence model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law. Horizontal axis: v2: Final volume V₂ (V₁ = 1.0 L) / L. Vertical axis: W ROUTE B (V₁ THEN p₂) / J. Exact values are available in the data table below.84.34100.5116.6132.7148.81.6872.2182.753.2823.813xy

Horizontal axis (x): v2: Final volume V₂ (V₁ = 1.0 L) / L

Axes show the supplied calibration interval; the origin may lie outside the plot.

Reading 1v2: Final volume V₂ (V₁ = 1.0 L) / L: 1.766W ROUTE B (V₁ THEN p₂) / J: 86.73
Read the exact data as a table
W ROUTE B (V₁ THEN p₂) against v2 — supplied values
v2: Final volume V₂ (V₁ = 1.0 L) / LW ROUTE B (V₁ THEN p₂) / J
1.76562586.72566371681415
2.2578125111.41868512110726
2.75127.27272727272727
3.2421875138.3132530120482
3.734375146.44351464435147

These are the supplied values, not a worked answer. No fitted trend is drawn.

Show a hint

The model's endpoint predictions bracket the reading. Solve Y_out(v2) = Y_measured and then solve again at Y_measured − u and Y_measured + u; a nonlinear inverse can give unequal input deviations.

Reveal the worked solution
  1. Endpoint predictions are Y_out(1.76563) = 86.7257 J and Y_out(3.73438) = 146.444 J. The target lies between them. On the selected branch the response is strictly increasing.
  2. Endpoint interpolation gives v2_line = 1.76563 + (132.582 − 86.7257)(3.73438 − 1.76563)/(146.444 − 86.7257) = 3.27739 L. This estimates the inverse of the endpoint chord, rather than assuming that chord is the physical model.
  3. Use the actual equation, not the chord, and bracket its root. Evaluating the midpoint and retaining the sign-changing half-interval gives v2 = 2.96656 L; substituting back gives Y_out = 132.5819 J.
  4. The interpolation error in the input is |v2_line − v2| = 0.310829 L. This is larger than the requested numerical tolerance.
  5. Invert both limits Y_out = 130.5027 J and 134.6611 J. Sort the roots even if the response decreases: 2.87781 L ≤ v2 ≤ 3.06096 L.
  6. The lower and upper input deviations are 0.0887528 L and 0.0944013 L. They differ because the inverse response is nonlinear; a symmetric error bar would only be a local approximation. This interval includes reading uncertainty only, not model error or uncertainty in fixed inputs.

Answer v2 ≈ 2.96656 L; compatible interval [2.87781, 3.06096] L. Endpoint interpolation gives 3.27739 L.

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.

Extra challenging · 03

Molar heat capacities and equipartition: infer an input with uncertainty

The molar heat capacity is the heat needed per mole per kelvin of temperature rise, C_V with the volume held fixed and C_p with the pressure held fixed; for an ideal gas C_p − C_V = R exactly. Use the supplied topic model Y_out = 8.314*(1.5+(2*tr/10^lt)^2*exp(-2*tr/10^lt)/max((1-exp(-2*tr/10^lt))^2,1e-9)+(tv/10^lt)^2*exp(-tv/10^lt)/max((1-exp(-tv/10^lt))^2,1e-9)), where Y_out is C_V (J K⁻¹ mol⁻¹). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793; exp(x) means eˣ; max(a,b) selects the larger value. tv is Vibrational temperature θ_vib, measured in K. Keep lt (Temperature log₁₀(T / K)) = 2.5; tr (Rotational temperature θ_rot) = 3 K fixed. For this exercise use only 958.75 K ≤ tv ≤ 5841.25 K on this continuous branch. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. A reading gives Y_out = 20.789799 J K⁻¹ mol⁻¹, with a bounded reading uncertainty ±0.00075322 J K⁻¹ mol⁻¹. Treat the model and all fixed inputs as exact for this exercise; the bound is not a standard deviation. First estimate the unknown tv by straight-line interpolation between the two endpoint predictions. Then solve the actual model on the stated branch to an absolute input tolerance of 0.48825 K, using a numerical bracket if required. Find the full input interval consistent with the bounded reading uncertainty and compare it with a symmetric input-error assumption. Do not assume that the supplied calibration points prove monotonicity outside this branch.

Explore the question data

C_V against tv

Predictions from the supplied Molar heat capacities and equipartition model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.

Vertical axis (y): C_V / J K⁻¹ mol⁻¹

C_V against tvPredictions from the supplied Molar heat capacities and equipartition model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law. Horizontal axis: tv: Vibrational temperature θ_vib / K. Vertical axis: C_V / J K⁻¹ mol⁻¹. Exact values are available in the data table below.20.6221.7222.8223.9225.02763.52082340047186037xy

Horizontal axis (x): tv: Vibrational temperature θ_vib / K

Axes show the supplied calibration interval; the origin may lie outside the plot.

Reading 1tv: Vibrational temperature θ_vib / K: 958.8C_V / J K⁻¹ mol⁻¹: 24.85
Read the exact data as a table
C_V against tv — supplied values
tv: Vibrational temperature θ_vib / KC_V / J K⁻¹ mol⁻¹
958.7524.853355093413025
2179.37521.186810787571044
340020.80532669765694
4620.62520.78555121386278
5841.2520.784777542264607

These are the supplied values, not a worked answer. No fitted trend is drawn.

Show a hint

The model's endpoint predictions bracket the reading. Solve Y_out(tv) = Y_measured and then solve again at Y_measured − u and Y_measured + u; a nonlinear inverse can give unequal input deviations.

Reveal the worked solution
  1. Endpoint predictions are Y_out(958.75) = 24.8534 J K⁻¹ mol⁻¹ and Y_out(5841.25) = 20.7848 J K⁻¹ mol⁻¹. The target lies between them. On the selected branch the response is strictly decreasing.
  2. Endpoint interpolation gives tv_line = 958.75 + (20.7898 − 24.8534)(5841.25 − 958.75)/(20.7848 − 24.8534) = 5835.22 K. This estimates the inverse of the endpoint chord, rather than assuming that chord is the physical model.
  3. Use the actual equation, not the chord, and bracket its root. Evaluating the midpoint and retaining the sign-changing half-interval gives tv = 3937.06 K; substituting back gives Y_out = 20.789799 J K⁻¹ mol⁻¹.
  4. The interpolation error in the input is |tv_line − tv| = 1898.16 K. This is larger than the requested numerical tolerance.
  5. Invert both limits Y_out = 20.789046 J K⁻¹ mol⁻¹ and 20.790552 J K⁻¹ mol⁻¹. Sort the roots even if the response decreases: 3884.6 K ≤ tv ≤ 3997.85 K.
  6. The lower and upper input deviations are 52.4598 K and 60.7848 K. They differ because the inverse response is nonlinear; a symmetric error bar would only be a local approximation. This interval includes reading uncertainty only, not model error or uncertainty in fixed inputs.

Answer tv ≈ 3937.06 K; compatible interval [3884.6, 3997.85] K. Endpoint interpolation gives 5835.22 K.

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.

Extra challenging · 04

Isothermal, isobaric, isochoric, and adiabatic processes: infer an input with uncertainty

A named gas process holds a single quantity fixed along the whole path — temperature, pressure, volume, or the heat transferred, which is zero — so that the first law fixes the remaining energy terms from the path alone. Use the supplied topic model Y_out = v2^(-gamma), where Y_out is p₂ ON THE ADIABAT (×10⁵ Pa). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793. v2 is Final volume V₂, measured in L. Keep gamma (Heat-capacity ratio γ) = 1.4 fixed. For this exercise use only 0.7125 L ≤ v2 ≤ 2.2875 L on this continuous branch. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. A reading gives Y_out = 0.48642382 ×10⁵ Pa, with a bounded reading uncertainty ±0.025867 ×10⁵ Pa. Treat the model and all fixed inputs as exact for this exercise; the bound is not a standard deviation. First estimate the unknown v2 by straight-line interpolation between the two endpoint predictions. Then solve the actual model on the stated branch to an absolute input tolerance of 0.0001575 L, using a numerical bracket if required. Find the full input interval consistent with the bounded reading uncertainty and compare it with a symmetric input-error assumption. Do not assume that the supplied calibration points prove monotonicity outside this branch.

Explore the question data

p₂ ON THE ADIABAT against v2

Predictions from the supplied Isothermal, isobaric, isochoric, and adiabatic processes model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.

Vertical axis (y): p₂ ON THE ADIABAT / ×10⁵ Pa

p₂ ON THE ADIABAT against v2Predictions from the supplied Isothermal, isobaric, isochoric, and adiabatic processes model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law. Horizontal axis: v2: Final volume V₂ / L. Vertical axis: p₂ ON THE ADIABAT / ×10⁵ Pa. Exact values are available in the data table below.0.26220.61140.96061.311.6590.64951.0751.51.9252.35xy

Horizontal axis (x): v2: Final volume V₂ / L

Axes show the supplied calibration interval; the origin may lie outside the plot.

Reading 1v2: Final volume V₂ / L: 0.7125p₂ ON THE ADIABAT / ×10⁵ Pa: 1.607
Read the exact data as a table
p₂ ON THE ADIABAT against v2 — supplied values
v2: Final volume V₂ / Lp₂ ON THE ADIABAT / ×10⁵ Pa
0.71251.607315688903108
1.106250.8681712559718779
1.50.5668553336114626
1.89374999999999980.4090235331274138
2.28749999999999960.31397455686962167

These are the supplied values, not a worked answer. No fitted trend is drawn.

Show a hint

The model's endpoint predictions bracket the reading. Solve Y_out(v2) = Y_measured and then solve again at Y_measured − u and Y_measured + u; a nonlinear inverse can give unequal input deviations.

Reveal the worked solution
  1. Endpoint predictions are Y_out(0.7125) = 1.60732 ×10⁵ Pa and Y_out(2.2875) = 0.313975 ×10⁵ Pa. The target lies between them. On the selected branch the response is strictly decreasing.
  2. Endpoint interpolation gives v2_line = 0.7125 + (0.486424 − 1.60732)(2.2875 − 0.7125)/(0.313975 − 1.60732) = 2.0775 L. This estimates the inverse of the endpoint chord, rather than assuming that chord is the physical model.
  3. Use the actual equation, not the chord, and bracket its root. Evaluating the midpoint and retaining the sign-changing half-interval gives v2 = 1.67325 L; substituting back gives Y_out = 0.48642382 ×10⁵ Pa.
  4. The interpolation error in the input is |v2_line − v2| = 0.404245 L. This is larger than the requested numerical tolerance.
  5. Invert both limits Y_out = 0.46055682 ×10⁵ Pa and 0.51229082 ×10⁵ Pa. Sort the roots even if the response decreases: 1.61246 L ≤ v2 ≤ 1.73985 L.
  6. The lower and upper input deviations are 0.0607929 L and 0.0666007 L. They differ because the inverse response is nonlinear; a symmetric error bar would only be a local approximation. This interval includes reading uncertainty only, not model error or uncertainty in fixed inputs.

Answer v2 ≈ 1.67325 L; compatible interval [1.61246, 1.73985] L. Endpoint interpolation gives 2.0775 L.

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.

Choose a topic