Skip to main content
Course and syllabus guidance

University Physics II · topic UPII-02.05

Fields from continuous charge

Connect the ideas, make your working visible, and test the result. Use the hints when you need a starting point; open the full solution after your attempt.

Further practice

Work through a fresh case before tackling the extension.

Further practice · 01

Fields from continuous charge: predict a finite change

A continuous charge distribution is a body described by a charge density rather than by a list of charges, so its field is found by integrating the point-charge field over the body instead of summing a finite number of terms. Use the supplied topic model Y_out = 28.2366*sig*rd*rd/(max(z,0.5)*max(z,0.5)), where Y_out is POINT-CHARGE ESTIMATE kQ/z² (N C⁻¹). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793; max(a,b) selects the larger value. z is Probe distance z along the axis, measured in cm. Keep rd (Disc radius R) = 8 cm; sig (Surface charge density σ) = 60 nC m⁻² fixed. For this exercise use only 3.63437 cm ≤ z ≤ 26.8656 cm on this continuous branch. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. Calculate Y_out at z = 8.74525 cm and 11.9976 cm. Find the signed output change ΔY_out and the average sensitivity ΔY_out/Δz across this interval. State whether the response increases or decreases; distinguish this interval average from a derivative at one point.

Explore the question data

POINT-CHARGE ESTIMATE kQ/z² against z

Predictions from the supplied Fields from continuous charge model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.

Vertical axis (y): POINT-CHARGE ESTIMATE kQ/z² / N C⁻¹

POINT-CHARGE ESTIMATE kQ/z² against zPredictions from the supplied Fields from continuous charge model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law. Horizontal axis: z: Probe distance z along the axis / cm. Vertical axis: POINT-CHARGE ESTIMATE kQ/z² / N C⁻¹. Exact values are available in the data table below.-172.120044180635585312.7058.97815.2521.5227.79xy

Horizontal axis (x): z: Probe distance z along the axis / cm

Axes show the supplied calibration interval; the origin may lie outside the plot.

Reading 1z: Probe distance z along the axis / cm: 3.634POINT-CHARGE ESTIMATE kQ/z² / N C⁻¹: 8209
Read the exact data as a table
POINT-CHARGE ESTIMATE kQ/z² against z — supplied values
z: Probe distance z along the axis / cmPOINT-CHARGE ESTIMATE kQ/z² / N C⁻¹
3.6343758208.884652538984
9.44218751216.1814794294157
15.25466.23399731255034
21.057812499999997244.52153714718938
26.865624999999998150.2276000231584

These are the supplied values, not a worked answer. No fitted trend is drawn.

Show a hint

Substitute each value of z separately while keeping every other input fixed, then subtract in the same order.

Reveal the worked solution
  1. At z = 8.74525 cm, substitute into Y_out = 28.2366*sig*rd*rd/(max(z,0.5)*max(z,0.5)): Y₀ = 1417.75 N C⁻¹.
  2. At z = 11.9976 cm, the same fixed-parameter model gives Y₁ = 753.274 N C⁻¹.
  3. Signed change: ΔY_out = Y₁ − Y₀ = -664.474 N C⁻¹; the input change is Δz = 3.25237 cm.
  4. Average sensitivity is ΔY_out/Δz = -204.304 N C⁻¹ per cm. Its negative sign means that this response decreases over the specified interval.
  5. This is a secant slope between two settings. It equals a point derivative only for a locally linear relation or in a justified small-interval limit.

Answer Y₀ = 1417.75 N C⁻¹, Y₁ = 753.274 N C⁻¹; ΔY_out = -664.474 N C⁻¹; average sensitivity = -204.304 N C⁻¹ per cm.

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.

Extra challenging questions

Work through the linked stages and explain what each result means.

Extra challenging · 01

Fields from continuous charge: infer an input with uncertainty

A continuous charge distribution is a body described by a charge density rather than by a list of charges, so its field is found by integrating the point-charge field over the body instead of summing a finite number of terms. Use the supplied topic model Y_out = 28.2366*sig*rd*rd/(max(z,0.5)*max(z,0.5)), where Y_out is POINT-CHARGE ESTIMATE kQ/z² (N C⁻¹). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793; max(a,b) selects the larger value. z is Probe distance z along the axis, measured in cm. Keep rd (Disc radius R) = 8 cm; sig (Surface charge density σ) = 60 nC m⁻² fixed. For this exercise use only 3.63437 cm ≤ z ≤ 26.8656 cm on this continuous branch. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. A reading gives Y_out = 342.00962 N C⁻¹, with a bounded reading uncertainty ±28.767 N C⁻¹. Treat the model and all fixed inputs as exact for this exercise; the bound is not a standard deviation. First estimate the unknown z by straight-line interpolation between the two endpoint predictions. Then solve the actual model on the stated branch to an absolute input tolerance of 0.00232313 cm, using a numerical bracket if required. Find the full input interval consistent with the bounded reading uncertainty and compare it with a symmetric input-error assumption. Do not assume that the supplied calibration points prove monotonicity outside this branch.

Explore the question data

POINT-CHARGE ESTIMATE kQ/z² against z

Predictions from the supplied Fields from continuous charge model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.

Vertical axis (y): POINT-CHARGE ESTIMATE kQ/z² / N C⁻¹

POINT-CHARGE ESTIMATE kQ/z² against zPredictions from the supplied Fields from continuous charge model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law. Horizontal axis: z: Probe distance z along the axis / cm. Vertical axis: POINT-CHARGE ESTIMATE kQ/z² / N C⁻¹. Exact values are available in the data table below.-172.120044180635585312.7058.97815.2521.5227.79xy

Horizontal axis (x): z: Probe distance z along the axis / cm

Axes show the supplied calibration interval; the origin may lie outside the plot.

Reading 1z: Probe distance z along the axis / cm: 3.634POINT-CHARGE ESTIMATE kQ/z² / N C⁻¹: 8209
Read the exact data as a table
POINT-CHARGE ESTIMATE kQ/z² against z — supplied values
z: Probe distance z along the axis / cmPOINT-CHARGE ESTIMATE kQ/z² / N C⁻¹
3.6343758208.884652538984
9.44218751216.1814794294157
15.25466.23399731255034
21.057812499999997244.52153714718938
26.865624999999998150.2276000231584

These are the supplied values, not a worked answer. No fitted trend is drawn.

Show a hint

The model's endpoint predictions bracket the reading. Solve Y_out(z) = Y_measured and then solve again at Y_measured − u and Y_measured + u; a nonlinear inverse can give unequal input deviations.

Reveal the worked solution
  1. Endpoint predictions are Y_out(3.63437) = 8208.88 N C⁻¹ and Y_out(26.8656) = 150.228 N C⁻¹. The target lies between them. On the selected branch the response is strictly decreasing.
  2. Endpoint interpolation gives z_line = 3.63437 + (342.01 − 8208.88)(26.8656 − 3.63437)/(150.228 − 8208.88) = 26.3128 cm. This estimates the inverse of the endpoint chord, rather than assuming that chord is the physical model.
  3. Use the actual equation, not the chord, and bracket its root. Evaluating the midpoint and retaining the sign-changing half-interval gives z = 17.8054 cm; substituting back gives Y_out = 342.00962 N C⁻¹.
  4. The interpolation error in the input is |z_line − z| = 8.50732 cm. This is larger than the requested numerical tolerance.
  5. Invert both limits Y_out = 313.24262 N C⁻¹ and 370.77662 N C⁻¹. Sort the roots even if the response decreases: 17.1008 cm ≤ z ≤ 18.6051 cm.
  6. The lower and upper input deviations are 0.704669 cm and 0.799636 cm. They differ because the inverse response is nonlinear; a symmetric error bar would only be a local approximation. This interval includes reading uncertainty only, not model error or uncertainty in fixed inputs.

Answer z ≈ 17.8054 cm; compatible interval [17.1008, 18.6051] cm. Endpoint interpolation gives 26.3128 cm.

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.