Skip to main content
Course and syllabus guidance

University Physics II · topic UPII-12.07

Electromagnetic energy and momentum

Connect the ideas, make your working visible, and test the result. Use the hints when you need a starting point; open the full solution after your attempt.

Further practice

Work through a fresh case before tackling the extension.

Further practice · 01

Electromagnetic energy and momentum: predict a finite change

The Poynting vector S⃗ = (1/μ₀) E⃗ × B⃗ gives the power per unit area an electromagnetic field transports and the direction it flows. Its cycle average is the intensity, and I/c is the momentum delivered per second per unit area. Use the supplied topic model Y_out = 0.0013272*E0^2, where Y_out is INTENSITY I = ½ε₀cE₀² (W m⁻²). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793. E0 is Peak electric field E₀, measured in V m⁻¹. Keep R (Reflectance R of the surface) = 0 fixed. For this exercise use only 885 V m⁻¹ ≤ E0 ≤ 1515 V m⁻¹ on this continuous branch. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. Calculate Y_out at E0 = 1023.6 V m⁻¹ and 1111.8 V m⁻¹. Find the signed output change ΔY_out and the average sensitivity ΔY_out/ΔE0 across this interval. State whether the response increases or decreases; distinguish this interval average from a derivative at one point.

Explore the question data

INTENSITY I = ½ε₀cE₀² against E0

Predictions from the supplied Electromagnetic energy and momentum model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.

Vertical axis (y): INTENSITY I = ½ε₀cE₀² / W m⁻²

INTENSITY I = ½ε₀cE₀² against E0Predictions from the supplied Electromagnetic energy and momentum model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law. Horizontal axis: E0: Peak electric field E₀ / V m⁻¹. Vertical axis: INTENSITY I = ½ε₀cE₀² / W m⁻². Exact values are available in the data table below.959.21501204325853126859.81030120013701540xy

Horizontal axis (x): E0: Peak electric field E₀ / V m⁻¹

Axes show the supplied calibration interval; the origin may lie outside the plot.

Reading 1E0: Peak electric field E₀ / V m⁻¹: 885INTENSITY I = ½ε₀cE₀² / W m⁻²: 1039
Read the exact data as a table
INTENSITY I = ½ε₀cE₀² against E0 — supplied values
E0: Peak electric field E₀ / V m⁻¹INTENSITY I = ½ε₀cE₀² / W m⁻²
8851039.49622
1042.51442.409255
12001911.168
1357.52445.772455
15153046.22262

These are the supplied values, not a worked answer. No fitted trend is drawn.

Show a hint

Substitute each value of E0 separately while keeping every other input fixed, then subtract in the same order.

Reveal the worked solution
  1. At E0 = 1023.6 V m⁻¹, substitute into Y_out = 0.0013272*E0^2: Y₀ = 1390.58 W m⁻².
  2. At E0 = 1111.8 V m⁻¹, the same fixed-parameter model gives Y₁ = 1640.55 W m⁻².
  3. Signed change: ΔY_out = Y₁ − Y₀ = 249.968 W m⁻²; the input change is ΔE0 = 88.2 V m⁻¹.
  4. Average sensitivity is ΔY_out/ΔE0 = 2.8341 W m⁻² per V m⁻¹. Its positive sign means that this response increases over the specified interval.
  5. This is a secant slope between two settings. It equals a point derivative only for a locally linear relation or in a justified small-interval limit.

Answer Y₀ = 1390.58 W m⁻², Y₁ = 1640.55 W m⁻²; ΔY_out = 249.968 W m⁻²; average sensitivity = 2.8341 W m⁻² per V m⁻¹.

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.

Extra challenging questions

Work through the linked stages and explain what each result means.

Extra challenging · 01

Electromagnetic energy and momentum: infer an input with uncertainty

The Poynting vector S⃗ = (1/μ₀) E⃗ × B⃗ gives the power per unit area an electromagnetic field transports and the direction it flows. Its cycle average is the intensity, and I/c is the momentum delivered per second per unit area. Use the supplied topic model Y_out = 0.0013272*E0^2, where Y_out is INTENSITY I = ½ε₀cE₀² (W m⁻²). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793. E0 is Peak electric field E₀, measured in V m⁻¹. Keep R (Reflectance R of the surface) = 0 fixed. For this exercise use only 885 V m⁻¹ ≤ E0 ≤ 1515 V m⁻¹ on this continuous branch. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. A reading gives Y_out = 2138.2818 W m⁻², with a bounded reading uncertainty ±136.19 W m⁻². Treat the model and all fixed inputs as exact for this exercise; the bound is not a standard deviation. First estimate the unknown E0 by straight-line interpolation between the two endpoint predictions. Then solve the actual model on the stated branch to an absolute input tolerance of 0.063 V m⁻¹, using a numerical bracket if required. Find the full input interval consistent with the bounded reading uncertainty and compare it with a symmetric input-error assumption. Do not assume that the supplied calibration points prove monotonicity outside this branch.

Explore the question data

INTENSITY I = ½ε₀cE₀² against E0

Predictions from the supplied Electromagnetic energy and momentum model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.

Vertical axis (y): INTENSITY I = ½ε₀cE₀² / W m⁻²

INTENSITY I = ½ε₀cE₀² against E0Predictions from the supplied Electromagnetic energy and momentum model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law. Horizontal axis: E0: Peak electric field E₀ / V m⁻¹. Vertical axis: INTENSITY I = ½ε₀cE₀² / W m⁻². Exact values are available in the data table below.959.21501204325853126859.81030120013701540xy

Horizontal axis (x): E0: Peak electric field E₀ / V m⁻¹

Axes show the supplied calibration interval; the origin may lie outside the plot.

Reading 1E0: Peak electric field E₀ / V m⁻¹: 885INTENSITY I = ½ε₀cE₀² / W m⁻²: 1039
Read the exact data as a table
INTENSITY I = ½ε₀cE₀² against E0 — supplied values
E0: Peak electric field E₀ / V m⁻¹INTENSITY I = ½ε₀cE₀² / W m⁻²
8851039.49622
1042.51442.409255
12001911.168
1357.52445.772455
15153046.22262

These are the supplied values, not a worked answer. No fitted trend is drawn.

Show a hint

The model's endpoint predictions bracket the reading. Solve Y_out(E0) = Y_measured and then solve again at Y_measured − u and Y_measured + u; a nonlinear inverse can give unequal input deviations.

Reveal the worked solution
  1. Endpoint predictions are Y_out(885) = 1039.5 W m⁻² and Y_out(1515) = 3046.22 W m⁻². The target lies between them. On the selected branch the response is strictly increasing.
  2. Endpoint interpolation gives E0_line = 885 + (2138.28 − 1039.5)(1515 − 885)/(3046.22 − 1039.5) = 1229.96 V m⁻¹. This estimates the inverse of the endpoint chord, rather than assuming that chord is the physical model.
  3. Use the actual equation, not the chord, and bracket its root. Evaluating the midpoint and retaining the sign-changing half-interval gives E0 = 1269.3 V m⁻¹; substituting back gives Y_out = 2138.2818 W m⁻².
  4. The interpolation error in the input is |E0_line − E0| = 39.3427 V m⁻¹. This is larger than the requested numerical tolerance.
  5. Invert both limits Y_out = 2002.0918 W m⁻² and 2274.4718 W m⁻². Sort the roots even if the response decreases: 1228.21 V m⁻¹ ≤ E0 ≤ 1309.1 V m⁻¹.
  6. The lower and upper input deviations are 41.0867 V m⁻¹ and 39.7978 V m⁻¹. They differ because the inverse response is nonlinear; a symmetric error bar would only be a local approximation. This interval includes reading uncertainty only, not model error or uncertainty in fixed inputs.

Answer E0 ≈ 1269.3 V m⁻¹; compatible interval [1228.21, 1309.1] V m⁻¹. Endpoint interpolation gives 1229.96 V m⁻¹.

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.