Skip to main content
Course and syllabus guidance

University Physics II · topic UPII-14.03

Multiple slits and diffraction gratings

Connect the ideas, make your working visible, and test the result. Use the hints when you need a starting point; open the full solution after your attempt.

Further practice

Work through a fresh case before tackling the extension.

Further practice · 01

Multiple Slits & Diffraction Gratings: predict a finite change

A diffraction grating is a large number of identical, equally spaced slits, and it sends sharp principal maxima in the directions where the path difference between neighbouring slits is a whole number of wavelengths. Use the supplied topic model Y_out = q, where Y_out is ENVELOPE ZERO AT m = (dimensionless). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793. q is Spacing / slit width d/a, dimensionless. Keep n (Slits illuminated N) = 5; r (Spacing / wavelength d/λ) = 3.5 fixed. For this exercise use only 2.2125 ≤ q ≤ 3.7875 on this continuous branch. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. Calculate Y_out at q = 2.559 and 2.7795. Find the signed output change ΔY_out and the average sensitivity ΔY_out/Δq across this interval. State whether the response increases or decreases; distinguish this interval average from a derivative at one point.

Explore the question data

ENVELOPE ZERO AT m = against q

Predictions from the supplied Multiple Slits & Diffraction Gratings model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.

Vertical axis (y): ENVELOPE ZERO AT m =

ENVELOPE ZERO AT m = against qPredictions from the supplied Multiple Slits & Diffraction Gratings model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law. Horizontal axis: q: Spacing / slit width d/a. Vertical axis: ENVELOPE ZERO AT m =. Exact values are available in the data table below.2.1492.57533.4253.852.1492.57533.4253.85xy

Horizontal axis (x): q: Spacing / slit width d/a

Axes show the supplied calibration interval; the origin may lie outside the plot.

Reading 1q: Spacing / slit width d/a: 2.212ENVELOPE ZERO AT m =: 2.212
Read the exact data as a table
ENVELOPE ZERO AT m = against q — supplied values
q: Spacing / slit width d/aENVELOPE ZERO AT m =
2.21252.2125
2.60624999999999972.6062499999999997
33
3.393753.39375
3.78749999999999963.7874999999999996

These are the supplied values, not a worked answer. No fitted trend is drawn.

Show a hint

Substitute each value of q separately while keeping every other input fixed, then subtract in the same order.

Reveal the worked solution
  1. At q = 2.559, substitute into Y_out = q: Y₀ = 2.559.
  2. At q = 2.7795, the same fixed-parameter model gives Y₁ = 2.7795.
  3. Signed change: ΔY_out = Y₁ − Y₀ = 0.2205; the input change is Δq = 0.2205.
  4. Average sensitivity is ΔY_out/Δq = 1 1 per unit input. Its positive sign means that this response increases over the specified interval.
  5. This is a secant slope between two settings. It equals a point derivative only for a locally linear relation or in a justified small-interval limit.

Answer Y₀ = 2.559, Y₁ = 2.7795; ΔY_out = 0.2205; average sensitivity = 1 1 per unit input.

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.

Extra challenging questions

Work through the linked stages and explain what each result means.

Extra challenging · 01

Multiple Slits & Diffraction Gratings: infer an input with uncertainty

A diffraction grating is a large number of identical, equally spaced slits, and it sends sharp principal maxima in the directions where the path difference between neighbouring slits is a whole number of wavelengths. Use the supplied topic model Y_out = q, where Y_out is ENVELOPE ZERO AT m = (dimensionless). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793. q is Spacing / slit width d/a, dimensionless. Keep n (Slits illuminated N) = 5; r (Spacing / wavelength d/λ) = 3.5 fixed. For this exercise use only 2.2125 ≤ q ≤ 3.7875 on this continuous branch. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. A reading gives Y_out = 3.17325, with a bounded reading uncertainty ±0.092137. Treat the model and all fixed inputs as exact for this exercise; the bound is not a standard deviation. First estimate the unknown q by straight-line interpolation between the two endpoint predictions. Then solve the actual model on the stated branch to an absolute input tolerance of 0.0001575, using a numerical bracket if required. Find the full input interval consistent with the bounded reading uncertainty and compare it with a symmetric input-error assumption. Do not assume that the supplied calibration points prove monotonicity outside this branch.

Explore the question data

ENVELOPE ZERO AT m = against q

Predictions from the supplied Multiple Slits & Diffraction Gratings model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.

Vertical axis (y): ENVELOPE ZERO AT m =

ENVELOPE ZERO AT m = against qPredictions from the supplied Multiple Slits & Diffraction Gratings model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law. Horizontal axis: q: Spacing / slit width d/a. Vertical axis: ENVELOPE ZERO AT m =. Exact values are available in the data table below.2.1492.57533.4253.852.1492.57533.4253.85xy

Horizontal axis (x): q: Spacing / slit width d/a

Axes show the supplied calibration interval; the origin may lie outside the plot.

Reading 1q: Spacing / slit width d/a: 2.212ENVELOPE ZERO AT m =: 2.212
Read the exact data as a table
ENVELOPE ZERO AT m = against q — supplied values
q: Spacing / slit width d/aENVELOPE ZERO AT m =
2.21252.2125
2.60624999999999972.6062499999999997
33
3.393753.39375
3.78749999999999963.7874999999999996

These are the supplied values, not a worked answer. No fitted trend is drawn.

Show a hint

The model's endpoint predictions bracket the reading. Solve Y_out(q) = Y_measured and then solve again at Y_measured − u and Y_measured + u; a nonlinear inverse can give unequal input deviations.

Reveal the worked solution
  1. Endpoint predictions are Y_out(2.2125) = 2.2125 and Y_out(3.7875) = 3.7875. The target lies between them. On the selected branch the response is strictly increasing.
  2. Endpoint interpolation gives q_line = 2.2125 + (3.17325 − 2.2125)(3.7875 − 2.2125)/(3.7875 − 2.2125) = 3.17325. This estimates the inverse of the endpoint chord, rather than assuming that chord is the physical model.
  3. Use the actual equation, not the chord, and bracket its root. Evaluating the midpoint and retaining the sign-changing half-interval gives q = 3.17325; substituting back gives Y_out = 3.17325.
  4. The interpolation error in the input is |q_line − q| = 4.44089e-16. This is within the requested numerical tolerance.
  5. Invert both limits Y_out = 3.081113 and 3.265387. Sort the roots even if the response decreases: 3.08111 ≤ q ≤ 3.26539.
  6. The lower and upper input deviations are 0.092137 and 0.092137. They agree on this branch; this does not establish linearity for changes in other inputs or outside the interval. This interval includes reading uncertainty only, not model error or uncertainty in fixed inputs.

Answer q ≈ 3.17325; compatible interval [3.08111, 3.26539]. Endpoint interpolation gives 3.17325.

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.