Refrigerators and heat pumps
Connect the ideas, make your working visible, and test the result. Use the hints when you need a starting point; open the full solution after your attempt.
Further practice
Work through a fresh case before tackling the extension.
Refrigerators and heat pumps: predict a finite change
A refrigerator or heat pump is a cycle driven by a work input that carries heat from a cold reservoir to a hot one, and its coefficient of performance is the heat handled at whichever reservoir you care about divided by the work consumed. Use the supplied topic model Y_out = f*tc/lift+1, where Y_out is HEATING COP Q_H/W (dimensionless). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793. lift is Temperature lift T_H − T_C, measured in K. Keep tc (Cold space T_C) = 270 K; f (Fraction of the Carnot ceiling) = 0.35 fixed. For this exercise use only 35.3125 K ≤ lift ≤ 74.6875 K on this continuous branch. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. Calculate Y_out at lift = 43.975 K and 49.4875 K. Find the signed output change ΔY_out and the average sensitivity ΔY_out/Δlift across this interval. State whether the response increases or decreases; distinguish this interval average from a derivative at one point.
HEATING COP Q_H/W against lift
Predictions from the supplied Refrigerators and heat pumps model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.
Vertical axis (y): HEATING COP Q_H/W
Horizontal axis (x): lift: Temperature lift T_H − T_C / K
Axes show the supplied calibration interval; the origin may lie outside the plot.
Read the exact data as a table
| lift: Temperature lift T_H − T_C / K | HEATING COP Q_H/W |
|---|---|
| 35.3125 | 3.6761061946902656 |
| 45.15625 | 3.092733564013841 |
| 55 | 2.7181818181818183 |
| 64.84375 | 2.4573493975903613 |
| 74.6875 | 2.2652719665271968 |
These are the supplied values, not a worked answer. No fitted trend is drawn.
Show a hint
Substitute each value of lift separately while keeping every other input fixed, then subtract in the same order.
Reveal the worked solution
- At lift = 43.975 K, substitute into Y_out = f*tc/lift+1: Y₀ = 3.14895.
- At lift = 49.4875 K, the same fixed-parameter model gives Y₁ = 2.90957.
- Signed change: ΔY_out = Y₁ − Y₀ = -0.239375; the input change is Δlift = 5.5125 K.
- Average sensitivity is ΔY_out/Δlift = -0.0434241 1 per K. Its negative sign means that this response decreases over the specified interval.
- This is a secant slope between two settings. It equals a point derivative only for a locally linear relation or in a justified small-interval limit.
Answer Y₀ = 3.14895, Y₁ = 2.90957; ΔY_out = -0.239375; average sensitivity = -0.0434241 1 per K.
Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.
Extra challenging questions
Work through the linked stages and explain what each result means.
Refrigerators and heat pumps: infer an input with uncertainty
A refrigerator or heat pump is a cycle driven by a work input that carries heat from a cold reservoir to a hot one, and its coefficient of performance is the heat handled at whichever reservoir you care about divided by the work consumed. Use the supplied topic model Y_out = f*tc/lift+1, where Y_out is HEATING COP Q_H/W (dimensionless). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793. lift is Temperature lift T_H − T_C, measured in K. Keep tc (Cold space T_C) = 270 K; f (Fraction of the Carnot ceiling) = 0.35 fixed. For this exercise use only 35.3125 K ≤ lift ≤ 74.6875 K on this continuous branch. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. A reading gives Y_out = 2.5927526, with a bounded reading uncertainty ±0.049122. Treat the model and all fixed inputs as exact for this exercise; the bound is not a standard deviation. First estimate the unknown lift by straight-line interpolation between the two endpoint predictions. Then solve the actual model on the stated branch to an absolute input tolerance of 0.0039375 K, using a numerical bracket if required. Find the full input interval consistent with the bounded reading uncertainty and compare it with a symmetric input-error assumption. Do not assume that the supplied calibration points prove monotonicity outside this branch.
HEATING COP Q_H/W against lift
Predictions from the supplied Refrigerators and heat pumps model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.
Vertical axis (y): HEATING COP Q_H/W
Horizontal axis (x): lift: Temperature lift T_H − T_C / K
Axes show the supplied calibration interval; the origin may lie outside the plot.
Read the exact data as a table
| lift: Temperature lift T_H − T_C / K | HEATING COP Q_H/W |
|---|---|
| 35.3125 | 3.6761061946902656 |
| 45.15625 | 3.092733564013841 |
| 55 | 2.7181818181818183 |
| 64.84375 | 2.4573493975903613 |
| 74.6875 | 2.2652719665271968 |
These are the supplied values, not a worked answer. No fitted trend is drawn.
Show a hint
The model's endpoint predictions bracket the reading. Solve Y_out(lift) = Y_measured and then solve again at Y_measured − u and Y_measured + u; a nonlinear inverse can give unequal input deviations.
Reveal the worked solution
- Endpoint predictions are Y_out(35.3125) = 3.67611 and Y_out(74.6875) = 2.26527. The target lies between them. On the selected branch the response is strictly decreasing.
- Endpoint interpolation gives lift_line = 35.3125 + (2.59275 − 3.67611)(74.6875 − 35.3125)/(2.26527 − 3.67611) = 65.5478 K. This estimates the inverse of the endpoint chord, rather than assuming that chord is the physical model.
- Use the actual equation, not the chord, and bracket its root. Evaluating the midpoint and retaining the sign-changing half-interval gives lift = 59.3312 K; substituting back gives Y_out = 2.5927526.
- The interpolation error in the input is |lift_line − lift| = 6.21659 K. This is larger than the requested numerical tolerance.
- Invert both limits Y_out = 2.5436306 and 2.6418746. Sort the roots even if the response decreases: 57.5562 K ≤ lift ≤ 61.2193 K.
- The lower and upper input deviations are 1.77509 K and 1.88806 K. They differ because the inverse response is nonlinear; a symmetric error bar would only be a local approximation. This interval includes reading uncertainty only, not model error or uncertainty in fixed inputs.
Answer lift ≈ 59.3312 K; compatible interval [57.5562, 61.2193] K. Endpoint interpolation gives 65.5478 K.
Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.