Skip to main content
Course and syllabus guidance

University Physics II · topic UPII-E3.08

Entropy and irreversibility

Connect the ideas, make your working visible, and test the result. Use the hints when you need a starting point; open the full solution after your attempt.

Further practice

Work through a fresh case before tackling the extension.

Further practice · 01

Entropy and irreversibility: predict a finite change

Entropy is a state function whose change between two equilibrium states equals the heat absorbed divided by the absolute temperature, summed along any reversible path joining them — and whose total over a system and its surroundings never decreases. Use the supplied topic model Y_out = q/tc, where Y_out is COLD +Q/T_c (J K⁻¹). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793. tc is Cold reservoir T_c, measured in K. Keep th (Hot reservoir T_h) = 600 K; q (Heat conducted Q) = 1200 J fixed. For this exercise use only 253.125 K ≤ tc ≤ 646.875 K on this continuous branch. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. Calculate Y_out at tc = 339.75 K and 394.875 K. Find the signed output change ΔY_out and the average sensitivity ΔY_out/Δtc across this interval. State whether the response increases or decreases; distinguish this interval average from a derivative at one point.

Explore the question data

COLD +Q/T_c against tc

Predictions from the supplied Entropy and irreversibility model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.

Vertical axis (y): COLD +Q/T_c / J K⁻¹

COLD +Q/T_c against tcPredictions from the supplied Entropy and irreversibility model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law. Horizontal axis: tc: Cold reservoir T_c / K. Vertical axis: COLD +Q/T_c / J K⁻¹. Exact values are available in the data table below.1.742.5193.2984.0774.856237.4343.7450556.3662.6xy

Horizontal axis (x): tc: Cold reservoir T_c / K

Axes show the supplied calibration interval; the origin may lie outside the plot.

Reading 1tc: Cold reservoir T_c / K: 253.1COLD +Q/T_c / J K⁻¹: 4.741
Read the exact data as a table
COLD +Q/T_c against tc — supplied values
tc: Cold reservoir T_c / KCOLD +Q/T_c / J K⁻¹
253.1254.7407407407407405
351.56253.4133333333333336
4502.6666666666666665
548.43752.1880341880341883
646.8751.855072463768116

These are the supplied values, not a worked answer. No fitted trend is drawn.

Show a hint

Substitute each value of tc separately while keeping every other input fixed, then subtract in the same order.

Reveal the worked solution
  1. At tc = 339.75 K, substitute into Y_out = q/tc: Y₀ = 3.53201 J K⁻¹.
  2. At tc = 394.875 K, the same fixed-parameter model gives Y₁ = 3.03894 J K⁻¹.
  3. Signed change: ΔY_out = Y₁ − Y₀ = -0.493072 J K⁻¹; the input change is Δtc = 55.125 K.
  4. Average sensitivity is ΔY_out/Δtc = -0.00894463 J K⁻¹ per K. Its negative sign means that this response decreases over the specified interval.
  5. This is a secant slope between two settings. It equals a point derivative only for a locally linear relation or in a justified small-interval limit.

Answer Y₀ = 3.53201 J K⁻¹, Y₁ = 3.03894 J K⁻¹; ΔY_out = -0.493072 J K⁻¹; average sensitivity = -0.00894463 J K⁻¹ per K.

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.

Extra challenging questions

Work through the linked stages and explain what each result means.

Extra challenging · 01

Entropy and irreversibility: infer an input with uncertainty

Entropy is a state function whose change between two equilibrium states equals the heat absorbed divided by the absolute temperature, summed along any reversible path joining them — and whose total over a system and its surroundings never decreases. Use the supplied topic model Y_out = q/tc, where Y_out is COLD +Q/T_c (J K⁻¹). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793. tc is Cold reservoir T_c, measured in K. Keep th (Hot reservoir T_h) = 600 K; q (Heat conducted Q) = 1200 J fixed. For this exercise use only 253.125 K ≤ tc ≤ 646.875 K on this continuous branch. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. A reading gives Y_out = 2.4325352 J K⁻¹, with a bounded reading uncertainty ±0.086619 J K⁻¹. Treat the model and all fixed inputs as exact for this exercise; the bound is not a standard deviation. First estimate the unknown tc by straight-line interpolation between the two endpoint predictions. Then solve the actual model on the stated branch to an absolute input tolerance of 0.039375 K, using a numerical bracket if required. Find the full input interval consistent with the bounded reading uncertainty and compare it with a symmetric input-error assumption. Do not assume that the supplied calibration points prove monotonicity outside this branch.

Explore the question data

COLD +Q/T_c against tc

Predictions from the supplied Entropy and irreversibility model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.

Vertical axis (y): COLD +Q/T_c / J K⁻¹

COLD +Q/T_c against tcPredictions from the supplied Entropy and irreversibility model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law. Horizontal axis: tc: Cold reservoir T_c / K. Vertical axis: COLD +Q/T_c / J K⁻¹. Exact values are available in the data table below.1.742.5193.2984.0774.856237.4343.7450556.3662.6xy

Horizontal axis (x): tc: Cold reservoir T_c / K

Axes show the supplied calibration interval; the origin may lie outside the plot.

Reading 1tc: Cold reservoir T_c / K: 253.1COLD +Q/T_c / J K⁻¹: 4.741
Read the exact data as a table
COLD +Q/T_c against tc — supplied values
tc: Cold reservoir T_c / KCOLD +Q/T_c / J K⁻¹
253.1254.7407407407407405
351.56253.4133333333333336
4502.6666666666666665
548.43752.1880341880341883
646.8751.855072463768116

These are the supplied values, not a worked answer. No fitted trend is drawn.

Show a hint

The model's endpoint predictions bracket the reading. Solve Y_out(tc) = Y_measured and then solve again at Y_measured − u and Y_measured + u; a nonlinear inverse can give unequal input deviations.

Reveal the worked solution
  1. Endpoint predictions are Y_out(253.125) = 4.74074 J K⁻¹ and Y_out(646.875) = 1.85507 J K⁻¹. The target lies between them. On the selected branch the response is strictly decreasing.
  2. Endpoint interpolation gives tc_line = 253.125 + (2.43254 − 4.74074)(646.875 − 253.125)/(1.85507 − 4.74074) = 568.08 K. This estimates the inverse of the endpoint chord, rather than assuming that chord is the physical model.
  3. Use the actual equation, not the chord, and bracket its root. Evaluating the midpoint and retaining the sign-changing half-interval gives tc = 493.312 K; substituting back gives Y_out = 2.4325352 J K⁻¹.
  4. The interpolation error in the input is |tc_line − tc| = 74.7676 K. This is larger than the requested numerical tolerance.
  5. Invert both limits Y_out = 2.3459162 J K⁻¹ and 2.5191542 J K⁻¹. Sort the roots even if the response decreases: 476.35 K ≤ tc ≤ 511.527 K.
  6. The lower and upper input deviations are 16.9621 K and 18.2147 K. They differ because the inverse response is nonlinear; a symmetric error bar would only be a local approximation. This interval includes reading uncertainty only, not model error or uncertainty in fixed inputs.

Answer tc ≈ 493.312 K; compatible interval [476.35, 511.527] K. Endpoint interpolation gives 568.08 K.

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.