Skip to main content
Course and syllabus guidance

University Physics III · topic UPIII-06.06

The Maxwell-Boltzmann speed distribution

Connect the ideas, make your working visible, and test the result. Use the hints when you need a starting point; open the full solution after your attempt.

Further practice

Work through a fresh case before tackling the extension.

Further practice · 01

The Maxwell-Boltzmann speed distribution: predict a finite change

The Maxwell-Boltzmann speed distribution f(v) is the probability density of molecular speed in a classical gas at equilibrium: f(v) dv is the fraction of molecules whose speeds lie between v and v + dv, and the density integrates to 1 over all speeds. Use the supplied topic model Y_out = vs^2*m/(16629*t), where Y_out is EXPONENT x² = mv₀²/2kT (dimensionless). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793. t is Temperature T, measured in K. Keep m (Molar mass M) = 28 g mol⁻¹; vs (Threshold speed v₀) = 1000 m s⁻¹ fixed. For this exercise use only 285 K ≤ t ≤ 915 K on this continuous branch. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. Calculate Y_out at t = 423.6 K and 511.8 K. Find the signed output change ΔY_out and the average sensitivity ΔY_out/Δt across this interval. State whether the response increases or decreases; distinguish this interval average from a derivative at one point.

Explore the question data

EXPONENT x² = mv₀²/2kT against t

Predictions from the supplied The Maxwell-Boltzmann speed distribution model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.

Vertical axis (y): EXPONENT x² = mv₀²/2kT

EXPONENT x² = mv₀²/2kT against tPredictions from the supplied The Maxwell-Boltzmann speed distribution model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law. Horizontal axis: t: Temperature T / K. Vertical axis: EXPONENT x² = mv₀²/2kT. Exact values are available in the data table below.1.6782.7763.8744.9726.071259.8429.9600770.1940.2xy

Horizontal axis (x): t: Temperature T / K

Axes show the supplied calibration interval; the origin may lie outside the plot.

Reading 1t: Temperature T / K: 285EXPONENT x² = mv₀²/2kT: 5.908
Read the exact data as a table
EXPONENT x² = mv₀²/2kT against t — supplied values
t: Temperature T / KEXPONENT x² = mv₀²/2kT
2855.908089123524428
442.53.805209943964886
6002.8063423336741034
757.52.222845412811171
9151.8402244810977728

These are the supplied values, not a worked answer. No fitted trend is drawn.

Show a hint

Substitute each value of t separately while keeping every other input fixed, then subtract in the same order.

Reveal the worked solution
  1. At t = 423.6 K, substitute into Y_out = vs^2*m/(16629*t): Y₀ = 3.97499.
  2. At t = 511.8 K, the same fixed-parameter model gives Y₁ = 3.28997.
  3. Signed change: ΔY_out = Y₁ − Y₀ = -0.685022; the input change is Δt = 88.2 K.
  4. Average sensitivity is ΔY_out/Δt = -0.00776668 1 per K. Its negative sign means that this response decreases over the specified interval.
  5. This is a secant slope between two settings. It equals a point derivative only for a locally linear relation or in a justified small-interval limit.

Answer Y₀ = 3.97499, Y₁ = 3.28997; ΔY_out = -0.685022; average sensitivity = -0.00776668 1 per K.

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.

Extra challenging questions

Work through the linked stages and explain what each result means.

Extra challenging · 01

The Maxwell-Boltzmann speed distribution: infer an input with uncertainty

The Maxwell-Boltzmann speed distribution f(v) is the probability density of molecular speed in a classical gas at equilibrium: f(v) dv is the fraction of molecules whose speeds lie between v and v + dv, and the density integrates to 1 over all speeds. Use the supplied topic model Y_out = vs^2*m/(16629*t), where Y_out is EXPONENT x² = mv₀²/2kT (dimensionless). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793. t is Temperature T, measured in K. Keep m (Molar mass M) = 28 g mol⁻¹; vs (Threshold speed v₀) = 1000 m s⁻¹ fixed. For this exercise use only 285 K ≤ t ≤ 915 K on this continuous branch. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. A reading gives Y_out = 2.5157708, with a bounded reading uncertainty ±0.10133. Treat the model and all fixed inputs as exact for this exercise; the bound is not a standard deviation. First estimate the unknown t by straight-line interpolation between the two endpoint predictions. Then solve the actual model on the stated branch to an absolute input tolerance of 0.063 K, using a numerical bracket if required. Find the full input interval consistent with the bounded reading uncertainty and compare it with a symmetric input-error assumption. Do not assume that the supplied calibration points prove monotonicity outside this branch.

Explore the question data

EXPONENT x² = mv₀²/2kT against t

Predictions from the supplied The Maxwell-Boltzmann speed distribution model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.

Vertical axis (y): EXPONENT x² = mv₀²/2kT

EXPONENT x² = mv₀²/2kT against tPredictions from the supplied The Maxwell-Boltzmann speed distribution model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law. Horizontal axis: t: Temperature T / K. Vertical axis: EXPONENT x² = mv₀²/2kT. Exact values are available in the data table below.1.6782.7763.8744.9726.071259.8429.9600770.1940.2xy

Horizontal axis (x): t: Temperature T / K

Axes show the supplied calibration interval; the origin may lie outside the plot.

Reading 1t: Temperature T / K: 285EXPONENT x² = mv₀²/2kT: 5.908
Read the exact data as a table
EXPONENT x² = mv₀²/2kT against t — supplied values
t: Temperature T / KEXPONENT x² = mv₀²/2kT
2855.908089123524428
442.53.805209943964886
6002.8063423336741034
757.52.222845412811171
9151.8402244810977728

These are the supplied values, not a worked answer. No fitted trend is drawn.

Show a hint

The model's endpoint predictions bracket the reading. Solve Y_out(t) = Y_measured and then solve again at Y_measured − u and Y_measured + u; a nonlinear inverse can give unequal input deviations.

Reveal the worked solution
  1. Endpoint predictions are Y_out(285) = 5.90809 and Y_out(915) = 1.84022. The target lies between them. On the selected branch the response is strictly decreasing.
  2. Endpoint interpolation gives t_line = 285 + (2.51577 − 5.90809)(915 − 285)/(1.84022 − 5.90809) = 810.377 K. This estimates the inverse of the endpoint chord, rather than assuming that chord is the physical model.
  3. Use the actual equation, not the chord, and bracket its root. Evaluating the midpoint and retaining the sign-changing half-interval gives t = 669.3 K; substituting back gives Y_out = 2.5157708.
  4. The interpolation error in the input is |t_line − t| = 141.077 K. This is larger than the requested numerical tolerance.
  5. Invert both limits Y_out = 2.4144408 and 2.6171008. Sort the roots even if the response decreases: 643.386 K ≤ t ≤ 697.389 K.
  6. The lower and upper input deviations are 25.9142 K and 28.0894 K. They differ because the inverse response is nonlinear; a symmetric error bar would only be a local approximation. This interval includes reading uncertainty only, not model error or uncertainty in fixed inputs.

Answer t ≈ 669.3 K; compatible interval [643.386, 697.389] K. Endpoint interpolation gives 810.377 K.

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.