Skip to main content
Course and syllabus guidance

University Physics IV · topic UPIV-01.04

Planck's quantised oscillator and the radiation law

Connect the ideas, make your working visible, and test the result. Use the hints when you need a starting point; open the full solution after your attempt.

Further practice

Work through a fresh case before tackling the extension.

Further practice · 01

Planck's quantised oscillator and the radiation law: predict a finite change

The Planck distribution gives the energy per unit volume per unit frequency inside a cavity at temperature T, by multiplying the classical count of standing modes by the mean energy hν/(e^(hν/kT) − 1) of an oscillator whose energies are restricted to whole multiples of hν. Use the supplied topic model Y_out = (4799.2*f/t)/(exp(4799.2*f/t)-1), where Y_out is ⟨E⟩ / kT AT PROBE (dimensionless). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793; exp(x) means eˣ. f is Probe frequency ν, measured in ×10¹⁴ Hz. Keep t (Temperature T) = 5800 K fixed. For this exercise use only 0.795 ×10¹⁴ Hz ≤ f ≤ 5.205 ×10¹⁴ Hz on this continuous branch. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. Calculate Y_out at f = 1.7652 ×10¹⁴ Hz and 2.3826 ×10¹⁴ Hz. Find the signed output change ΔY_out and the average sensitivity ΔY_out/Δf across this interval. State whether the response increases or decreases; distinguish this interval average from a derivative at one point.

Explore the question data

⟨E⟩ / kT AT PROBE against f

Predictions from the supplied Planck's quantised oscillator and the radiation law model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.

Vertical axis (y): ⟨E⟩ / kT AT PROBE

⟨E⟩ / kT AT PROBE against fPredictions from the supplied Planck's quantised oscillator and the radiation law model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law. Horizontal axis: f: Probe frequency ν / ×10¹⁴ Hz. Vertical axis: ⟨E⟩ / kT AT PROBE. Exact values are available in the data table below.0.032910.20790.38290.55780.73280.61861.80934.1915.381xy

Horizontal axis (x): f: Probe frequency ν / ×10¹⁴ Hz

Axes show the supplied calibration interval; the origin may lie outside the plot.

Reading 1f: Probe frequency ν / ×10¹⁴ Hz: 0.795⟨E⟩ / kT AT PROBE: 0.7069
Read the exact data as a table
⟨E⟩ / kT AT PROBE against f — supplied values
f: Probe frequency ν / ×10¹⁴ Hz⟨E⟩ / kT AT PROBE
0.79499999999999990.706892633004084
1.89749999999999970.41241487995723425
2.99999999999999960.22629934438934565
4.1024999999999990.11785631220721395
5.2049999999999990.058830788498718166

These are the supplied values, not a worked answer. No fitted trend is drawn.

Show a hint

Substitute each value of f separately while keeping every other input fixed, then subtract in the same order.

Reveal the worked solution
  1. At f = 1.7652 ×10¹⁴ Hz, substitute into Y_out = (4799.2*f/t)/(exp(4799.2*f/t)-1): Y₀ = 0.44146.
  2. At f = 2.3826 ×10¹⁴ Hz, the same fixed-parameter model gives Y₁ = 0.318943.
  3. Signed change: ΔY_out = Y₁ − Y₀ = -0.122517; the input change is Δf = 0.6174 ×10¹⁴ Hz.
  4. Average sensitivity is ΔY_out/Δf = -0.19844 1 per ×10¹⁴ Hz. Its negative sign means that this response decreases over the specified interval.
  5. This is a secant slope between two settings. It equals a point derivative only for a locally linear relation or in a justified small-interval limit.

Answer Y₀ = 0.44146, Y₁ = 0.318943; ΔY_out = -0.122517; average sensitivity = -0.19844 1 per ×10¹⁴ Hz.

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.

Extra challenging questions

Work through the linked stages and explain what each result means.

Extra challenging · 01

Planck's quantised oscillator and the radiation law: infer an input with uncertainty

The Planck distribution gives the energy per unit volume per unit frequency inside a cavity at temperature T, by multiplying the classical count of standing modes by the mean energy hν/(e^(hν/kT) − 1) of an oscillator whose energies are restricted to whole multiples of hν. Use the supplied topic model Y_out = (4799.2*f/t)/(exp(4799.2*f/t)-1), where Y_out is ⟨E⟩ / kT AT PROBE (dimensionless). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793; exp(x) means eˣ. f is Probe frequency ν, measured in ×10¹⁴ Hz. Keep t (Temperature T) = 5800 K fixed. For this exercise use only 0.795 ×10¹⁴ Hz ≤ f ≤ 5.205 ×10¹⁴ Hz on this continuous branch. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. A reading gives Y_out = 0.17082732, with a bounded reading uncertainty ±0.016799. Treat the model and all fixed inputs as exact for this exercise; the bound is not a standard deviation. First estimate the unknown f by straight-line interpolation between the two endpoint predictions. Then solve the actual model on the stated branch to an absolute input tolerance of 0.000441 ×10¹⁴ Hz, using a numerical bracket if required. Find the full input interval consistent with the bounded reading uncertainty and compare it with a symmetric input-error assumption. Do not assume that the supplied calibration points prove monotonicity outside this branch.

Explore the question data

⟨E⟩ / kT AT PROBE against f

Predictions from the supplied Planck's quantised oscillator and the radiation law model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.

Vertical axis (y): ⟨E⟩ / kT AT PROBE

⟨E⟩ / kT AT PROBE against fPredictions from the supplied Planck's quantised oscillator and the radiation law model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law. Horizontal axis: f: Probe frequency ν / ×10¹⁴ Hz. Vertical axis: ⟨E⟩ / kT AT PROBE. Exact values are available in the data table below.0.032910.20790.38290.55780.73280.61861.80934.1915.381xy

Horizontal axis (x): f: Probe frequency ν / ×10¹⁴ Hz

Axes show the supplied calibration interval; the origin may lie outside the plot.

Reading 1f: Probe frequency ν / ×10¹⁴ Hz: 0.795⟨E⟩ / kT AT PROBE: 0.7069
Read the exact data as a table
⟨E⟩ / kT AT PROBE against f — supplied values
f: Probe frequency ν / ×10¹⁴ Hz⟨E⟩ / kT AT PROBE
0.79499999999999990.706892633004084
1.89749999999999970.41241487995723425
2.99999999999999960.22629934438934565
4.1024999999999990.11785631220721395
5.2049999999999990.058830788498718166

These are the supplied values, not a worked answer. No fitted trend is drawn.

Show a hint

The model's endpoint predictions bracket the reading. Solve Y_out(f) = Y_measured and then solve again at Y_measured − u and Y_measured + u; a nonlinear inverse can give unequal input deviations.

Reveal the worked solution
  1. Endpoint predictions are Y_out(0.795) = 0.706893 and Y_out(5.205) = 0.0588308. The target lies between them. On the selected branch the response is strictly decreasing.
  2. Endpoint interpolation gives f_line = 0.795 + (0.170827 − 0.706893)(5.205 − 0.795)/(0.0588308 − 0.706893) = 4.44287 ×10¹⁴ Hz. This estimates the inverse of the endpoint chord, rather than assuming that chord is the physical model.
  3. Use the actual equation, not the chord, and bracket its root. Evaluating the midpoint and retaining the sign-changing half-interval gives f = 3.4851 ×10¹⁴ Hz; substituting back gives Y_out = 0.17082732.
  4. The interpolation error in the input is |f_line − f| = 0.957774 ×10¹⁴ Hz. This is larger than the requested numerical tolerance.
  5. Invert both limits Y_out = 0.15402832 and 0.18762632. Sort the roots even if the response decreases: 3.32513 ×10¹⁴ Hz ≤ f ≤ 3.65969 ×10¹⁴ Hz.
  6. The lower and upper input deviations are 0.159972 ×10¹⁴ Hz and 0.174586 ×10¹⁴ Hz. They differ because the inverse response is nonlinear; a symmetric error bar would only be a local approximation. This interval includes reading uncertainty only, not model error or uncertainty in fixed inputs.

Answer f ≈ 3.4851 ×10¹⁴ Hz; compatible interval [3.32513, 3.65969] ×10¹⁴ Hz. Endpoint interpolation gives 4.44287 ×10¹⁴ Hz.

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.