Skip to main content
Course and syllabus guidance

University Physics IV · topic UPIV-12.07

Band filling, conduction, metals and insulators

Connect the ideas, make your working visible, and test the result. Use the hints when you need a starting point; open the full solution after your attempt.

Further practice

Work through a fresh case before tackling the extension.

Further practice · 01

Band filling, metals and insulators: predict a finite change

A solid is a metal when its highest occupied band is only partly filled, so empty states lie immediately above the last occupied one; it is an insulator or a semiconductor when every occupied band is exactly full and an energy gap separates it from the next empty band. Use the supplied topic model Y_out = 100-100*acos(clamp(z-3+2*eg*(clamp((z-1)/2,0,1)-1)/w,-1,1))/pi, where Y_out is UPPER BAND FILLED (%). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793; clamp(x,a,b) confines x to [a,b]; unmarked trigonometric functions use radians. z is Valence electrons per primitive cell, measured in e/cell. Keep eg (Gap at the zone edge (negative = overlap)) = 1.1 eV; w (Width of each band) = 2.4 eV fixed. For this exercise use only 2.3425 e/cell ≤ z ≤ 3.68125 e/cell on this continuous branch. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. Calculate Y_out at z = 2.63703 e/cell and 2.82445 e/cell. Find the signed output change ΔY_out and the average sensitivity ΔY_out/Δz across this interval. State whether the response increases or decreases; distinguish this interval average from a derivative at one point.

Explore the question data

UPPER BAND FILLED against z

Predictions from the supplied Band filling, metals and insulators model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.

Vertical axis (y): UPPER BAND FILLED / %

UPPER BAND FILLED against zPredictions from the supplied Band filling, metals and insulators model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law. Horizontal axis: z: Valence electrons per primitive cell / e/cell. Vertical axis: UPPER BAND FILLED / %. Exact values are available in the data table below.6.57524.0441.5158.9876.442.2892.653.0123.3733.735xy

Horizontal axis (x): z: Valence electrons per primitive cell / e/cell

Axes show the supplied calibration interval; the origin may lie outside the plot.

Reading 1z: Valence electrons per primitive cell / e/cell: 2.343UPPER BAND FILLED / %: 9.163
Read the exact data as a table
UPPER BAND FILLED against z — supplied values
z: Valence electrons per primitive cell / e/cellUPPER BAND FILLED / %
2.34250000000000029.162806936615112
2.677187534.397680270589504
3.01187550.378001874226655
3.346562561.26511432751862
3.6812573.85633324508629

These are the supplied values, not a worked answer. No fitted trend is drawn.

Show a hint

Substitute each value of z separately while keeping every other input fixed, then subtract in the same order.

Reveal the worked solution
  1. At z = 2.63703 e/cell, substitute into Y_out = 100-100*acos(clamp(z-3+2*eg*(clamp((z-1)/2,0,1)-1)/w,-1,1))/pi: Y₀ = 32.244 %.
  2. At z = 2.82445 e/cell, the same fixed-parameter model gives Y₁ = 41.7592 %.
  3. Signed change: ΔY_out = Y₁ − Y₀ = 9.51517 %; the input change is Δz = 0.187425 e/cell.
  4. Average sensitivity is ΔY_out/Δz = 50.7679 % per e/cell. Its positive sign means that this response increases over the specified interval.
  5. This is a secant slope between two settings. It equals a point derivative only for a locally linear relation or in a justified small-interval limit.

Answer Y₀ = 32.244 %, Y₁ = 41.7592 %; ΔY_out = 9.51517 %; average sensitivity = 50.7679 % per e/cell.

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.

Extra challenging questions

Work through the linked stages and explain what each result means.

Extra challenging · 01

Band filling, metals and insulators: infer an input with uncertainty

A solid is a metal when its highest occupied band is only partly filled, so empty states lie immediately above the last occupied one; it is an insulator or a semiconductor when every occupied band is exactly full and an energy gap separates it from the next empty band. Use the supplied topic model Y_out = 100-100*acos(clamp(z-3+2*eg*(clamp((z-1)/2,0,1)-1)/w,-1,1))/pi, where Y_out is UPPER BAND FILLED (%). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793; clamp(x,a,b) confines x to [a,b]; unmarked trigonometric functions use radians. z is Valence electrons per primitive cell, measured in e/cell. Keep eg (Gap at the zone edge (negative = overlap)) = 1.1 eV; w (Width of each band) = 2.4 eV fixed. For this exercise use only 2.3425 e/cell ≤ z ≤ 3.68125 e/cell on this continuous branch. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. A reading gives Y_out = 55.087132 %, with a bounded reading uncertainty ±2.8154 %. Treat the model and all fixed inputs as exact for this exercise; the bound is not a standard deviation. First estimate the unknown z by straight-line interpolation between the two endpoint predictions. Then solve the actual model on the stated branch to an absolute input tolerance of 0.000133875 e/cell, using a numerical bracket if required. Find the full input interval consistent with the bounded reading uncertainty and compare it with a symmetric input-error assumption. Do not assume that the supplied calibration points prove monotonicity outside this branch.

Explore the question data

UPPER BAND FILLED against z

Predictions from the supplied Band filling, metals and insulators model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.

Vertical axis (y): UPPER BAND FILLED / %

UPPER BAND FILLED against zPredictions from the supplied Band filling, metals and insulators model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law. Horizontal axis: z: Valence electrons per primitive cell / e/cell. Vertical axis: UPPER BAND FILLED / %. Exact values are available in the data table below.6.57524.0441.5158.9876.442.2892.653.0123.3733.735xy

Horizontal axis (x): z: Valence electrons per primitive cell / e/cell

Axes show the supplied calibration interval; the origin may lie outside the plot.

Reading 1z: Valence electrons per primitive cell / e/cell: 2.343UPPER BAND FILLED / %: 9.163
Read the exact data as a table
UPPER BAND FILLED against z — supplied values
z: Valence electrons per primitive cell / e/cellUPPER BAND FILLED / %
2.34250000000000029.162806936615112
2.677187534.397680270589504
3.01187550.378001874226655
3.346562561.26511432751862
3.6812573.85633324508629

These are the supplied values, not a worked answer. No fitted trend is drawn.

Show a hint

The model's endpoint predictions bracket the reading. Solve Y_out(z) = Y_measured and then solve again at Y_measured − u and Y_measured + u; a nonlinear inverse can give unequal input deviations.

Reveal the worked solution
  1. Endpoint predictions are Y_out(2.3425) = 9.16281 % and Y_out(3.68125) = 73.8563 %. The target lies between them. On the selected branch the response is strictly increasing.
  2. Endpoint interpolation gives z_line = 2.3425 + (55.0871 − 9.16281)(3.68125 − 2.3425)/(73.8563 − 9.16281) = 3.29285 e/cell. This estimates the inverse of the endpoint chord, rather than assuming that chord is the physical model.
  3. Use the actual equation, not the chord, and bracket its root. Evaluating the midpoint and retaining the sign-changing half-interval gives z = 3.15914 e/cell; substituting back gives Y_out = 55.087132 %.
  4. The interpolation error in the input is |z_line − z| = 0.133708 e/cell. This is larger than the requested numerical tolerance.
  5. Invert both limits Y_out = 52.271732 % and 57.902532 %. Sort the roots even if the response decreases: 3.07131 e/cell ≤ z ≤ 3.24572 e/cell.
  6. The lower and upper input deviations are 0.0878295 e/cell and 0.0865854 e/cell. They differ because the inverse response is nonlinear; a symmetric error bar would only be a local approximation. This interval includes reading uncertainty only, not model error or uncertainty in fixed inputs.

Answer z ≈ 3.15914 e/cell; compatible interval [3.07131, 3.24572] e/cell. Endpoint interpolation gives 3.29285 e/cell.

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.