Skip to main content
Course and syllabus guidance

University Quantum Field Theory I · topic UQFTI-02.07

Normal ordering and the contraction: T phi(x) phi(y) = :phi(x) phi(y): + D_F(x - y)

Connect the ideas, make your working visible, and test the result. Use the hints when you need a starting point; open the full solution after your attempt.

Further practice

Work through a fresh case before tackling the extension.

Further practice · 01

Normal ordering and the contraction of two fields: predict a finite change

The contraction of two free fields is the c-number by which their time-ordered product exceeds their normal-ordered product; for a real scalar field it is the Feynman propagator D_F(x − y), the same in every matrix element. Use the supplied topic model Y_out = 4*nb*cos(mt-th*pi/180)*cosd(th), where Y_out is CLASSICAL PART, NORMAL-ORDERED ((2mV)⁻¹). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793; sind/cosd/tand use degrees; unmarked trigonometric functions use radians. th is Phase θ of the classical wave, measured in °. Keep nb (Mean number of quanta n̄) = 1; mt (Time separation m(x⁰ − y⁰)) = -2 fixed. For this exercise use only 127.8 ° ≤ th ≤ 160.875 ° on this continuous branch. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. Calculate Y_out at th = 135.077 ° and 139.707 °. Find the signed output change ΔY_out and the average sensitivity ΔY_out/Δth across this interval. State whether the response increases or decreases; distinguish this interval average from a derivative at one point.

Explore the question data

CLASSICAL PART, NORMAL-ORDERED against th

Predictions from the supplied Normal ordering and the contraction of two fields model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.

Vertical axis (y): CLASSICAL PART, NORMAL-ORDERED / (2mV)⁻¹

CLASSICAL PART, NORMAL-ORDERED against thPredictions from the supplied Normal ordering and the contraction of two fields model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law. Horizontal axis: th: Phase θ of the classical wave / °. Vertical axis: CLASSICAL PART, NORMAL-ORDERED / (2mV)⁻¹. Exact values are available in the data table below.-0.4199-0.015910.38810.7921.196126.5135.4144.3153.3162.2xy

Horizontal axis (x): th: Phase θ of the classical wave / °

Axes show the supplied calibration interval; the origin may lie outside the plot.

Reading 1th: Phase θ of the classical wave / °: 127.8CLASSICAL PART, NORMAL-ORDERED / (2mV)⁻¹: 1.136
Read the exact data as a table
CLASSICAL PART, NORMAL-ORDERED against th — supplied values
th: Phase θ of the classical wave / °CLASSICAL PART, NORMAL-ORDERED / (2mV)⁻¹
127.81.1361496987174535
136.068750.9539931064406244
144.33750.6240521570131798
152.606250.17362376136086233
160.875-0.36002691589858754

These are the supplied values, not a worked answer. No fitted trend is drawn.

Show a hint

Substitute each value of th separately while keeping every other input fixed, then subtract in the same order.

Reveal the worked solution
  1. At th = 135.077 °, substitute into Y_out = 4*nb*cos(mt-th*pi/180)*cosd(th): Y₀ = 0.984072 (2mV)⁻¹.
  2. At th = 139.707 °, the same fixed-parameter model gives Y₁ = 0.825673 (2mV)⁻¹.
  3. Signed change: ΔY_out = Y₁ − Y₀ = -0.158399 (2mV)⁻¹; the input change is Δth = 4.6305 °.
  4. Average sensitivity is ΔY_out/Δth = -0.0342078 (2mV)⁻¹ per °. Its negative sign means that this response decreases over the specified interval.
  5. This is a secant slope between two settings. It equals a point derivative only for a locally linear relation or in a justified small-interval limit.

Answer Y₀ = 0.984072 (2mV)⁻¹, Y₁ = 0.825673 (2mV)⁻¹; ΔY_out = -0.158399 (2mV)⁻¹; average sensitivity = -0.0342078 (2mV)⁻¹ per °.

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.

Extra challenging questions

Work through the linked stages and explain what each result means.

Extra challenging · 01

Normal ordering and the contraction of two fields: infer an input with uncertainty

The contraction of two free fields is the c-number by which their time-ordered product exceeds their normal-ordered product; for a real scalar field it is the Feynman propagator D_F(x − y), the same in every matrix element. Use the supplied topic model Y_out = 4*nb*cos(mt-th*pi/180)*cosd(th), where Y_out is CLASSICAL PART, NORMAL-ORDERED ((2mV)⁻¹). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793; sind/cosd/tand use degrees; unmarked trigonometric functions use radians. th is Phase θ of the classical wave, measured in °. Keep nb (Mean number of quanta n̄) = 1; mt (Time separation m(x⁰ − y⁰)) = -2 fixed. For this exercise use only 127.8 ° ≤ th ≤ 160.875 ° on this continuous branch. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. A reading gives Y_out = 0.43870262 (2mV)⁻¹, with a bounded reading uncertainty ±0.10462 (2mV)⁻¹. Treat the model and all fixed inputs as exact for this exercise; the bound is not a standard deviation. First estimate the unknown th by straight-line interpolation between the two endpoint predictions. Then solve the actual model on the stated branch to an absolute input tolerance of 0.0033075 °, using a numerical bracket if required. Find the full input interval consistent with the bounded reading uncertainty and compare it with a symmetric input-error assumption. Do not assume that the supplied calibration points prove monotonicity outside this branch.

Explore the question data

CLASSICAL PART, NORMAL-ORDERED against th

Predictions from the supplied Normal ordering and the contraction of two fields model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.

Vertical axis (y): CLASSICAL PART, NORMAL-ORDERED / (2mV)⁻¹

CLASSICAL PART, NORMAL-ORDERED against thPredictions from the supplied Normal ordering and the contraction of two fields model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law. Horizontal axis: th: Phase θ of the classical wave / °. Vertical axis: CLASSICAL PART, NORMAL-ORDERED / (2mV)⁻¹. Exact values are available in the data table below.-0.4199-0.015910.38810.7921.196126.5135.4144.3153.3162.2xy

Horizontal axis (x): th: Phase θ of the classical wave / °

Axes show the supplied calibration interval; the origin may lie outside the plot.

Reading 1th: Phase θ of the classical wave / °: 127.8CLASSICAL PART, NORMAL-ORDERED / (2mV)⁻¹: 1.136
Read the exact data as a table
CLASSICAL PART, NORMAL-ORDERED against th — supplied values
th: Phase θ of the classical wave / °CLASSICAL PART, NORMAL-ORDERED / (2mV)⁻¹
127.81.1361496987174535
136.068750.9539931064406244
144.33750.6240521570131798
152.606250.17362376136086233
160.875-0.36002691589858754

These are the supplied values, not a worked answer. No fitted trend is drawn.

Show a hint

The model's endpoint predictions bracket the reading. Solve Y_out(th) = Y_measured and then solve again at Y_measured − u and Y_measured + u; a nonlinear inverse can give unequal input deviations.

Reveal the worked solution
  1. Endpoint predictions are Y_out(127.8) = 1.13615 (2mV)⁻¹ and Y_out(160.875) = -0.360027 (2mV)⁻¹. The target lies between them. On the selected branch the response is strictly decreasing.
  2. Endpoint interpolation gives th_line = 127.8 + (0.438703 − 1.13615)(160.875 − 127.8)/(-0.360027 − 1.13615) = 143.218 °. This estimates the inverse of the endpoint chord, rather than assuming that chord is the physical model.
  3. Use the actual equation, not the chord, and bracket its root. Evaluating the midpoint and retaining the sign-changing half-interval gives th = 147.976 °; substituting back gives Y_out = 0.43870262 (2mV)⁻¹.
  4. The interpolation error in the input is |th_line − th| = 4.75774 °. This is larger than the requested numerical tolerance.
  5. Invert both limits Y_out = 0.33408262 (2mV)⁻¹ and 0.54332262 (2mV)⁻¹. Sort the roots even if the response decreases: 145.976 ° ≤ th ≤ 149.867 °.
  6. The lower and upper input deviations are 1.99996 ° and 1.89092 °. They differ because the inverse response is nonlinear; a symmetric error bar would only be a local approximation. This interval includes reading uncertainty only, not model error or uncertainty in fixed inputs.

Answer th ≈ 147.976 °; compatible interval [145.976, 149.867] °. Endpoint interpolation gives 143.218 °.

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.