Skip to main content
Course and syllabus guidance

University Quantum Field Theory I · topic UQFTI-04.03

The physical mass and the field-strength renormalisation Z, with 0 <= Z <= 1

Connect the ideas, make your working visible, and test the result. Use the hints when you need a starting point; open the full solution after your attempt.

Further practice

Work through a fresh case before tackling the extension.

Further practice · 01

Physical mass and field-strength renormalisation Z: predict a finite change

The physical mass m is the position of the exact propagator's one-particle pole, and the field-strength renormalisation Z is its residue, Z = |⟨Ω|φ(0)|p⟩|², the share of the field's total spectral weight that goes into making a single particle. Use the supplied topic model Y_out = gm^2/(16*pi^2)*(4*asin(r/2)/(r*sqrt(4-r^2))-1)/r^2, where Y_out is −dΣ/dp² AT p² = m² (dimensionless). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793; sqrt(x) means √x; unmarked trigonometric functions use radians. r is Mass ratio m/M, dimensionless. Keep gm (Coupling g/M) = 6 fixed. For this exercise use only 0.564688 ≤ r ≤ 1.78531 on this continuous branch. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. Calculate Y_out at r = 0.833225 and 1.00411. Find the signed output change ΔY_out and the average sensitivity ΔY_out/Δr across this interval. State whether the response increases or decreases; distinguish this interval average from a derivative at one point.

Explore the question data

−dΣ/dp² AT p² = m² against r

Predictions from the supplied Physical mass and field-strength renormalisation Z model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.

Vertical axis (y): −dΣ/dp² AT p² = m²

−dΣ/dp² AT p² = m² against rPredictions from the supplied Physical mass and field-strength renormalisation Z model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law. Horizontal axis: r: Mass ratio m/M. Vertical axis: −dΣ/dp² AT p² = m². Exact values are available in the data table below.0.037240.059910.082590.10530.12790.51590.84541.1751.5051.834xy

Horizontal axis (x): r: Mass ratio m/M

Axes show the supplied calibration interval; the origin may lie outside the plot.

Reading 1r: Mass ratio m/M: 0.5647−dΣ/dp² AT p² = m²: 0.0406
Read the exact data as a table
−dΣ/dp² AT p² = m² against r — supplied values
r: Mass ratio m/M−dΣ/dp² AT p² = m²
0.56468750.04059680288487651
0.869843750.0448667659309379
1.17499999999999980.05298261520393529
1.48015624999999980.07013520088792928
1.78531249999999990.12458649026796594

These are the supplied values, not a worked answer. No fitted trend is drawn.

Show a hint

Substitute each value of r separately while keeping every other input fixed, then subtract in the same order.

Reveal the worked solution
  1. At r = 0.833225, substitute into Y_out = gm^2/(16*pi^2)*(4*asin(r/2)/(r*sqrt(4-r^2))-1)/r^2: Y₀ = 0.0442.
  2. At r = 1.00411, the same fixed-parameter model gives Y₁ = 0.0477942.
  3. Signed change: ΔY_out = Y₁ − Y₀ = 0.00359429; the input change is Δr = 0.170887.
  4. Average sensitivity is ΔY_out/Δr = 0.0210331 1 per unit input. Its positive sign means that this response increases over the specified interval.
  5. This is a secant slope between two settings. It equals a point derivative only for a locally linear relation or in a justified small-interval limit.

Answer Y₀ = 0.0442, Y₁ = 0.0477942; ΔY_out = 0.00359429; average sensitivity = 0.0210331 1 per unit input.

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.

Extra challenging questions

Work through the linked stages and explain what each result means.

Extra challenging · 01

Physical mass and field-strength renormalisation Z: infer an input with uncertainty

The physical mass m is the position of the exact propagator's one-particle pole, and the field-strength renormalisation Z is its residue, Z = |⟨Ω|φ(0)|p⟩|², the share of the field's total spectral weight that goes into making a single particle. Use the supplied topic model Y_out = gm^2/(16*pi^2)*(4*asin(r/2)/(r*sqrt(4-r^2))-1)/r^2, where Y_out is −dΣ/dp² AT p² = m² (dimensionless). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793; sqrt(x) means √x; unmarked trigonometric functions use radians. r is Mass ratio m/M, dimensionless. Keep gm (Coupling g/M) = 6 fixed. For this exercise use only 0.564688 ≤ r ≤ 1.78531 on this continuous branch. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. A reading gives Y_out = 0.058809071, with a bounded reading uncertainty ±0.0027318. Treat the model and all fixed inputs as exact for this exercise; the bound is not a standard deviation. First estimate the unknown r by straight-line interpolation between the two endpoint predictions. Then solve the actual model on the stated branch to an absolute input tolerance of 0.000122062, using a numerical bracket if required. Find the full input interval consistent with the bounded reading uncertainty and compare it with a symmetric input-error assumption. Do not assume that the supplied calibration points prove monotonicity outside this branch.

Explore the question data

−dΣ/dp² AT p² = m² against r

Predictions from the supplied Physical mass and field-strength renormalisation Z model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.

Vertical axis (y): −dΣ/dp² AT p² = m²

−dΣ/dp² AT p² = m² against rPredictions from the supplied Physical mass and field-strength renormalisation Z model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law. Horizontal axis: r: Mass ratio m/M. Vertical axis: −dΣ/dp² AT p² = m². Exact values are available in the data table below.0.037240.059910.082590.10530.12790.51590.84541.1751.5051.834xy

Horizontal axis (x): r: Mass ratio m/M

Axes show the supplied calibration interval; the origin may lie outside the plot.

Reading 1r: Mass ratio m/M: 0.5647−dΣ/dp² AT p² = m²: 0.0406
Read the exact data as a table
−dΣ/dp² AT p² = m² against r — supplied values
r: Mass ratio m/M−dΣ/dp² AT p² = m²
0.56468750.04059680288487651
0.869843750.0448667659309379
1.17499999999999980.05298261520393529
1.48015624999999980.07013520088792928
1.78531249999999990.12458649026796594

These are the supplied values, not a worked answer. No fitted trend is drawn.

Show a hint

The model's endpoint predictions bracket the reading. Solve Y_out(r) = Y_measured and then solve again at Y_measured − u and Y_measured + u; a nonlinear inverse can give unequal input deviations.

Reveal the worked solution
  1. Endpoint predictions are Y_out(0.564688) = 0.0405968 and Y_out(1.78531) = 0.124586. The target lies between them. On the selected branch the response is strictly increasing.
  2. Endpoint interpolation gives r_line = 0.564688 + (0.0588091 − 0.0405968)(1.78531 − 0.564688)/(0.124586 − 0.0405968) = 0.829367. This estimates the inverse of the endpoint chord, rather than assuming that chord is the physical model.
  3. Use the actual equation, not the chord, and bracket its root. Evaluating the midpoint and retaining the sign-changing half-interval gives r = 1.30927; substituting back gives Y_out = 0.058809071.
  4. The interpolation error in the input is |r_line − r| = 0.479902. This is larger than the requested numerical tolerance.
  5. Invert both limits Y_out = 0.056077271 and 0.061540871. Sort the roots even if the response decreases: 1.25189 ≤ r ≤ 1.35901.
  6. The lower and upper input deviations are 0.0573796 and 0.0497367. They differ because the inverse response is nonlinear; a symmetric error bar would only be a local approximation. This interval includes reading uncertainty only, not model error or uncertainty in fixed inputs.

Answer r ≈ 1.30927; compatible interval [1.25189, 1.35901]. Endpoint interpolation gives 0.829367.

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.