Skip to main content
Course and syllabus guidance

University Quantum Field Theory I · topic UQFTI-04.07

Mandelstam variables and crossing symmetry for scalar amplitudes

Connect the ideas, make your working visible, and test the result. Use the hints when you need a starting point; open the full solution after your attempt.

Further practice

Work through a fresh case before tackling the extension.

Further practice · 01

Mandelstam variables and crossing symmetry: predict a finite change

The Mandelstam variables are the invariants s = (p₁ + p₂)², t = (p₁ − p₃)² and u = (p₁ − p₄)² of a two-to-two process, and crossing symmetry says one function of them, continued between regions, gives every process made by moving a particle across the reaction as its antiparticle. Use the supplied topic model Y_out = 1/(r^2+(s-4)*(1-cosd(th))/2)+1/(r^2+(s-4)*(1+cosd(th))/2), where Y_out is ℳ(ψψ → ψψ) / g² (M⁻²). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793; sind/cosd/tand use degrees. th is Centre-of-mass angle θ, measured in °. Keep r (Exchanged mass m) = 0.6 M; s (Centre-of-mass energy squared s) = 8 M² fixed. For this exercise use only 94.725 ° ≤ th ≤ 160.875 ° on this continuous branch. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. Calculate Y_out at th = 109.278 ° and 118.539 °. Find the signed output change ΔY_out and the average sensitivity ΔY_out/Δth across this interval. State whether the response increases or decreases; distinguish this interval average from a derivative at one point.

Explore the question data

ℳ(ψψ → ψψ) / g² against th

Predictions from the supplied Mandelstam variables and crossing symmetry model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.

Vertical axis (y): ℳ(ψψ → ψψ) / g² / M⁻²

ℳ(ψψ → ψψ) / g² against thPredictions from the supplied Mandelstam variables and crossing symmetry model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law. Horizontal axis: th: Centre-of-mass angle θ / °. Vertical axis: ℳ(ψψ → ψψ) / g² / M⁻². Exact values are available in the data table below.0.79121.1991.6062.0142.42292.08109.9127.8145.7163.5xy

Horizontal axis (x): th: Centre-of-mass angle θ / °

Axes show the supplied calibration interval; the origin may lie outside the plot.

Reading 1th: Centre-of-mass angle θ / °: 94.72ℳ(ψψ → ψψ) / g² / M⁻²: 0.8516
Read the exact data as a table
ℳ(ψψ → ψψ) / g² against th — supplied values
th: Centre-of-mass angle θ / °ℳ(ψψ → ψψ) / g² / M⁻²
94.7250.8516076372564418
111.262499999999990.9358459796698471
127.81.1605663814194687
144.33751.6113610916014043
160.8752.3612205878381034

These are the supplied values, not a worked answer. No fitted trend is drawn.

Show a hint

Substitute each value of th separately while keeping every other input fixed, then subtract in the same order.

Reveal the worked solution
  1. At th = 109.278 °, substitute into Y_out = 1/(r^2+(s-4)*(1-cosd(th))/2)+1/(r^2+(s-4)*(1+cosd(th))/2): Y₀ = 0.919433 M⁻².
  2. At th = 118.539 °, the same fixed-parameter model gives Y₁ = 1.01362 M⁻².
  3. Signed change: ΔY_out = Y₁ − Y₀ = 0.0941835 M⁻²; the input change is Δth = 9.261 °.
  4. Average sensitivity is ΔY_out/Δth = 0.0101699 M⁻² per °. Its positive sign means that this response increases over the specified interval.
  5. This is a secant slope between two settings. It equals a point derivative only for a locally linear relation or in a justified small-interval limit.

Answer Y₀ = 0.919433 M⁻², Y₁ = 1.01362 M⁻²; ΔY_out = 0.0941835 M⁻²; average sensitivity = 0.0101699 M⁻² per °.

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.

Extra challenging questions

Work through the linked stages and explain what each result means.

Extra challenging · 01

Mandelstam variables and crossing symmetry: infer an input with uncertainty

The Mandelstam variables are the invariants s = (p₁ + p₂)², t = (p₁ − p₃)² and u = (p₁ − p₄)² of a two-to-two process, and crossing symmetry says one function of them, continued between regions, gives every process made by moving a particle across the reaction as its antiparticle. Use the supplied topic model Y_out = 1/(r^2+(s-4)*(1-cosd(th))/2)+1/(r^2+(s-4)*(1+cosd(th))/2), where Y_out is ℳ(ψψ → ψψ) / g² (M⁻²). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793; sind/cosd/tand use degrees. th is Centre-of-mass angle θ, measured in °. Keep r (Exchanged mass m) = 0.6 M; s (Centre-of-mass energy squared s) = 8 M² fixed. For this exercise use only 94.725 ° ≤ th ≤ 160.875 ° on this continuous branch. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. A reading gives Y_out = 1.3242583 M⁻², with a bounded reading uncertainty ±0.070898 M⁻². Treat the model and all fixed inputs as exact for this exercise; the bound is not a standard deviation. First estimate the unknown th by straight-line interpolation between the two endpoint predictions. Then solve the actual model on the stated branch to an absolute input tolerance of 0.006615 °, using a numerical bracket if required. Find the full input interval consistent with the bounded reading uncertainty and compare it with a symmetric input-error assumption. Do not assume that the supplied calibration points prove monotonicity outside this branch.

Explore the question data

ℳ(ψψ → ψψ) / g² against th

Predictions from the supplied Mandelstam variables and crossing symmetry model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.

Vertical axis (y): ℳ(ψψ → ψψ) / g² / M⁻²

ℳ(ψψ → ψψ) / g² against thPredictions from the supplied Mandelstam variables and crossing symmetry model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law. Horizontal axis: th: Centre-of-mass angle θ / °. Vertical axis: ℳ(ψψ → ψψ) / g² / M⁻². Exact values are available in the data table below.0.79121.1991.6062.0142.42292.08109.9127.8145.7163.5xy

Horizontal axis (x): th: Centre-of-mass angle θ / °

Axes show the supplied calibration interval; the origin may lie outside the plot.

Reading 1th: Centre-of-mass angle θ / °: 94.72ℳ(ψψ → ψψ) / g² / M⁻²: 0.8516
Read the exact data as a table
ℳ(ψψ → ψψ) / g² against th — supplied values
th: Centre-of-mass angle θ / °ℳ(ψψ → ψψ) / g² / M⁻²
94.7250.8516076372564418
111.262499999999990.9358459796698471
127.81.1605663814194687
144.33751.6113610916014043
160.8752.3612205878381034

These are the supplied values, not a worked answer. No fitted trend is drawn.

Show a hint

The model's endpoint predictions bracket the reading. Solve Y_out(th) = Y_measured and then solve again at Y_measured − u and Y_measured + u; a nonlinear inverse can give unequal input deviations.

Reveal the worked solution
  1. Endpoint predictions are Y_out(94.725) = 0.851608 M⁻² and Y_out(160.875) = 2.36122 M⁻². The target lies between them. On the selected branch the response is strictly increasing.
  2. Endpoint interpolation gives th_line = 94.725 + (1.32426 − 0.851608)(160.875 − 94.725)/(2.36122 − 0.851608) = 115.436 °. This estimates the inverse of the endpoint chord, rather than assuming that chord is the physical model.
  3. Use the actual equation, not the chord, and bracket its root. Evaluating the midpoint and retaining the sign-changing half-interval gives th = 135.076 °; substituting back gives Y_out = 1.3242583 M⁻².
  4. The interpolation error in the input is |th_line − th| = 19.6403 °. This is larger than the requested numerical tolerance.
  5. Invert both limits Y_out = 1.2533603 M⁻² and 1.3951563 M⁻². Sort the roots even if the response decreases: 132.184 ° ≤ th ≤ 137.675 °.
  6. The lower and upper input deviations are 2.89248 ° and 2.59832 °. They differ because the inverse response is nonlinear; a symmetric error bar would only be a local approximation. This interval includes reading uncertainty only, not model error or uncertainty in fixed inputs.

Answer th ≈ 135.076 °; compatible interval [132.184, 137.675] °. Endpoint interpolation gives 115.436 °.

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.