Skip to main content
Course and syllabus guidance

University Quantum Field Theory I · topic UQFTI-09.07

Helicity amplitudes: why the angular distribution is (1 + cos theta)^2 + (1 - cos theta)^2

Connect the ideas, make your working visible, and test the result. Use the hints when you need a starting point; open the full solution after your attempt.

Further practice

Work through a fresh case before tackling the extension.

Further practice · 01

Helicity amplitudes and chirality conservation: predict a finite change

A helicity amplitude is M evaluated with every incoming and outgoing particle in a definite helicity state; squaring and summing over the helicities nobody measured gives back the spin-averaged |M|² that traces compute. Use the supplied topic model Y_out = sqrt(1-beta^2)*sind(theta), where Y_out is EACH FLIP |M|/e² (dimensionless). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793; sqrt(x) means √x; sind/cosd/tand use degrees. beta is Muon speed β, dimensionless. Keep theta (μ⁻ angle θ) = 60 ° fixed. For this exercise use only 0.105188 ≤ beta ≤ 0.884812 on this continuous branch. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. Calculate Y_out at beta = 0.276705 and 0.385852. Find the signed output change ΔY_out and the average sensitivity ΔY_out/Δbeta across this interval. State whether the response increases or decreases; distinguish this interval average from a derivative at one point.

Explore the question data

EACH FLIP |M|/e² against beta

Predictions from the supplied Helicity amplitudes and chirality conservation model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.

Vertical axis (y): EACH FLIP |M|/e²

EACH FLIP |M|/e² against betaPredictions from the supplied Helicity amplitudes and chirality conservation model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law. Horizontal axis: beta: Muon speed β. Vertical axis: EACH FLIP |M|/e². Exact values are available in the data table below.0.38520.50880.63240.7560.87950.0740.28450.4950.70550.916xy

Horizontal axis (x): beta: Muon speed β

Axes show the supplied calibration interval; the origin may lie outside the plot.

Reading 1beta: Muon speed β: 0.1052EACH FLIP |M|/e²: 0.8612
Read the exact data as a table
EACH FLIP |M|/e² against beta — supplied values
beta: Muon speed βEACH FLIP |M|/e²
0.10518750.8612210473408163
0.300093750.8261100446721387
0.494999999999999940.7524833885209693
0.68990624999999990.6269146869058048
0.88481249999999990.40352215538036157

These are the supplied values, not a worked answer. No fitted trend is drawn.

Show a hint

Substitute each value of beta separately while keeping every other input fixed, then subtract in the same order.

Reveal the worked solution
  1. At beta = 0.276705, substitute into Y_out = sqrt(1-beta^2)*sind(theta): Y₀ = 0.832211.
  2. At beta = 0.385852, the same fixed-parameter model gives Y₁ = 0.798961.
  3. Signed change: ΔY_out = Y₁ − Y₀ = -0.0332505; the input change is Δbeta = 0.109147.
  4. Average sensitivity is ΔY_out/Δbeta = -0.304639 1 per unit input. Its negative sign means that this response decreases over the specified interval.
  5. This is a secant slope between two settings. It equals a point derivative only for a locally linear relation or in a justified small-interval limit.

Answer Y₀ = 0.832211, Y₁ = 0.798961; ΔY_out = -0.0332505; average sensitivity = -0.304639 1 per unit input.

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.

Extra challenging questions

Work through the linked stages and explain what each result means.

Extra challenging · 01

Helicity amplitudes and chirality conservation: infer an input with uncertainty

A helicity amplitude is M evaluated with every incoming and outgoing particle in a definite helicity state; squaring and summing over the helicities nobody measured gives back the spin-averaged |M|² that traces compute. Use the supplied topic model Y_out = sqrt(1-beta^2)*sind(theta), where Y_out is EACH FLIP |M|/e² (dimensionless). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793; sqrt(x) means √x; sind/cosd/tand use degrees. beta is Muon speed β, dimensionless. Keep theta (μ⁻ angle θ) = 60 ° fixed. For this exercise use only 0.105188 ≤ beta ≤ 0.884812 on this continuous branch. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. A reading gives Y_out = 0.70501025, with a bounded reading uncertainty ±0.023432. Treat the model and all fixed inputs as exact for this exercise; the bound is not a standard deviation. First estimate the unknown beta by straight-line interpolation between the two endpoint predictions. Then solve the actual model on the stated branch to an absolute input tolerance of 0.0000779625, using a numerical bracket if required. Find the full input interval consistent with the bounded reading uncertainty and compare it with a symmetric input-error assumption. Do not assume that the supplied calibration points prove monotonicity outside this branch.

Explore the question data

EACH FLIP |M|/e² against beta

Predictions from the supplied Helicity amplitudes and chirality conservation model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.

Vertical axis (y): EACH FLIP |M|/e²

EACH FLIP |M|/e² against betaPredictions from the supplied Helicity amplitudes and chirality conservation model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law. Horizontal axis: beta: Muon speed β. Vertical axis: EACH FLIP |M|/e². Exact values are available in the data table below.0.38520.50880.63240.7560.87950.0740.28450.4950.70550.916xy

Horizontal axis (x): beta: Muon speed β

Axes show the supplied calibration interval; the origin may lie outside the plot.

Reading 1beta: Muon speed β: 0.1052EACH FLIP |M|/e²: 0.8612
Read the exact data as a table
EACH FLIP |M|/e² against beta — supplied values
beta: Muon speed βEACH FLIP |M|/e²
0.10518750.8612210473408163
0.300093750.8261100446721387
0.494999999999999940.7524833885209693
0.68990624999999990.6269146869058048
0.88481249999999990.40352215538036157

These are the supplied values, not a worked answer. No fitted trend is drawn.

Show a hint

The model's endpoint predictions bracket the reading. Solve Y_out(beta) = Y_measured and then solve again at Y_measured − u and Y_measured + u; a nonlinear inverse can give unequal input deviations.

Reveal the worked solution
  1. Endpoint predictions are Y_out(0.105188) = 0.861221 and Y_out(0.884812) = 0.403522. The target lies between them. On the selected branch the response is strictly decreasing.
  2. Endpoint interpolation gives beta_line = 0.105188 + (0.70501 − 0.861221)(0.884812 − 0.105188)/(0.403522 − 0.861221) = 0.37127. This estimates the inverse of the endpoint chord, rather than assuming that chord is the physical model.
  3. Use the actual equation, not the chord, and bracket its root. Evaluating the midpoint and retaining the sign-changing half-interval gives beta = 0.580759; substituting back gives Y_out = 0.70501025.
  4. The interpolation error in the input is |beta_line − beta| = 0.209488. This is larger than the requested numerical tolerance.
  5. Invert both limits Y_out = 0.68157825 and 0.72844225. Sort the roots even if the response decreases: 0.540829 ≤ beta ≤ 0.616929.
  6. The lower and upper input deviations are 0.0399299 and 0.0361703. They differ because the inverse response is nonlinear; a symmetric error bar would only be a local approximation. This interval includes reading uncertainty only, not model error or uncertainty in fixed inputs.

Answer beta ≈ 0.580759; compatible interval [0.540829, 0.616929]. Endpoint interpolation gives 0.37127.

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.