Skip to main content
Course and syllabus guidance

University Quantum Field Theory I · topic UQFTI-11.05

CPT invariance of every Hermitian, Lorentz-invariant Lagrangian, shown through bilinears

Connect the ideas, make your working visible, and test the result. Use the hints when you need a starting point; open the full solution after your attempt.

Further practice

Work through a fresh case before tackling the extension.

Further practice · 01

CPT invariance of Hermitian, Lorentz-invariant Lagrangians: predict a finite change

CPT invariance is the statement that the antiunitary product Θ = CPT maps the Lagrangian density at x onto the Lagrangian density at −x, so the action, and with it the dynamics, is unchanged even when C, P and T are separately broken. Use the supplied topic model Y_out = hypot((cos(pi*(n+q))-1)*cosd(delta), (cos(pi*(n+q))+1)*sind(delta)), where Y_out is IF CPT WERE LINEAR (|g|). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793; hypot(a,b) means √(a²+b²); sind/cosd/tand use degrees; unmarked trigonometric functions use radians. delta is Coupling phase δ, measured in °. Keep n (Field indices N (odd: background b_μ)) = 2; q (Commuting fermions q (0 no, 1 yes)) = 0 fixed. For this exercise use only 94.725 ° ≤ delta ≤ 160.875 ° on this continuous branch. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. Calculate Y_out at delta = 109.278 ° and 118.539 °. Find the signed output change ΔY_out and the average sensitivity ΔY_out/Δdelta across this interval. State whether the response increases or decreases; distinguish this interval average from a derivative at one point.

Explore the question data

IF CPT WERE LINEAR against delta

Predictions from the supplied CPT invariance of Hermitian, Lorentz-invariant Lagrangians model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.

Vertical axis (y): IF CPT WERE LINEAR / |g|

IF CPT WERE LINEAR against deltaPredictions from the supplied CPT invariance of Hermitian, Lorentz-invariant Lagrangians model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law. Horizontal axis: delta: Coupling phase δ / °. Vertical axis: IF CPT WERE LINEAR / |g|. Exact values are available in the data table below.0.60170.9631.3241.6852.04792.08109.9127.8145.7163.5xy

Horizontal axis (x): delta: Coupling phase δ / °

Axes show the supplied calibration interval; the origin may lie outside the plot.

Reading 1delta: Coupling phase δ / °: 94.72IF CPT WERE LINEAR / |g|: 1.993
Read the exact data as a table
IF CPT WERE LINEAR against delta — supplied values
delta: Coupling phase δ / °IF CPT WERE LINEAR / |g|
94.7251.9932030790546635
111.262499999999991.8638575507790025
127.81.580310024751381
144.33751.1660191579667014
160.8750.6552603591233874

These are the supplied values, not a worked answer. No fitted trend is drawn.

Show a hint

Substitute each value of delta separately while keeping every other input fixed, then subtract in the same order.

Reveal the worked solution
  1. At delta = 109.278 °, substitute into Y_out = hypot((cos(pi*(n+q))-1)*cosd(delta), (cos(pi*(n+q))+1)*sind(delta)): Y₀ = 1.88786 |g|.
  2. At delta = 118.539 °, the same fixed-parameter model gives Y₁ = 1.75698 |g|.
  3. Signed change: ΔY_out = Y₁ − Y₀ = -0.130871 |g|; the input change is Δdelta = 9.261 °.
  4. Average sensitivity is ΔY_out/Δdelta = -0.0141314 |g| per °. Its negative sign means that this response decreases over the specified interval.
  5. This is a secant slope between two settings. It equals a point derivative only for a locally linear relation or in a justified small-interval limit.

Answer Y₀ = 1.88786 |g|, Y₁ = 1.75698 |g|; ΔY_out = -0.130871 |g|; average sensitivity = -0.0141314 |g| per °.

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.

Extra challenging questions

Work through the linked stages and explain what each result means.

Extra challenging · 01

CPT invariance of Hermitian, Lorentz-invariant Lagrangians: infer an input with uncertainty

CPT invariance is the statement that the antiunitary product Θ = CPT maps the Lagrangian density at x onto the Lagrangian density at −x, so the action, and with it the dynamics, is unchanged even when C, P and T are separately broken. Use the supplied topic model Y_out = hypot((cos(pi*(n+q))-1)*cosd(delta), (cos(pi*(n+q))+1)*sind(delta)), where Y_out is IF CPT WERE LINEAR (|g|). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793; hypot(a,b) means √(a²+b²); sind/cosd/tand use degrees; unmarked trigonometric functions use radians. delta is Coupling phase δ, measured in °. Keep n (Field indices N (odd: background b_μ)) = 2; q (Commuting fermions q (0 no, 1 yes)) = 0 fixed. For this exercise use only 94.725 ° ≤ delta ≤ 160.875 ° on this continuous branch. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. A reading gives Y_out = 1.4123241 |g|, with a bounded reading uncertainty ±0.087132 |g|. Treat the model and all fixed inputs as exact for this exercise; the bound is not a standard deviation. First estimate the unknown delta by straight-line interpolation between the two endpoint predictions. Then solve the actual model on the stated branch to an absolute input tolerance of 0.006615 °, using a numerical bracket if required. Find the full input interval consistent with the bounded reading uncertainty and compare it with a symmetric input-error assumption. Do not assume that the supplied calibration points prove monotonicity outside this branch.

Explore the question data

IF CPT WERE LINEAR against delta

Predictions from the supplied CPT invariance of Hermitian, Lorentz-invariant Lagrangians model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.

Vertical axis (y): IF CPT WERE LINEAR / |g|

IF CPT WERE LINEAR against deltaPredictions from the supplied CPT invariance of Hermitian, Lorentz-invariant Lagrangians model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law. Horizontal axis: delta: Coupling phase δ / °. Vertical axis: IF CPT WERE LINEAR / |g|. Exact values are available in the data table below.0.60170.9631.3241.6852.04792.08109.9127.8145.7163.5xy

Horizontal axis (x): delta: Coupling phase δ / °

Axes show the supplied calibration interval; the origin may lie outside the plot.

Reading 1delta: Coupling phase δ / °: 94.72IF CPT WERE LINEAR / |g|: 1.993
Read the exact data as a table
IF CPT WERE LINEAR against delta — supplied values
delta: Coupling phase δ / °IF CPT WERE LINEAR / |g|
94.7251.9932030790546635
111.262499999999991.8638575507790025
127.81.580310024751381
144.33751.1660191579667014
160.8750.6552603591233874

These are the supplied values, not a worked answer. No fitted trend is drawn.

Show a hint

The model's endpoint predictions bracket the reading. Solve Y_out(delta) = Y_measured and then solve again at Y_measured − u and Y_measured + u; a nonlinear inverse can give unequal input deviations.

Reveal the worked solution
  1. Endpoint predictions are Y_out(94.725) = 1.9932 |g| and Y_out(160.875) = 0.65526 |g|. The target lies between them. On the selected branch the response is strictly decreasing.
  2. Endpoint interpolation gives delta_line = 94.725 + (1.41232 − 1.9932)(160.875 − 94.725)/(0.65526 − 1.9932) = 123.445 °. This estimates the inverse of the endpoint chord, rather than assuming that chord is the physical model.
  3. Use the actual equation, not the chord, and bracket its root. Evaluating the midpoint and retaining the sign-changing half-interval gives delta = 135.076 °; substituting back gives Y_out = 1.4123241 |g|.
  4. The interpolation error in the input is |delta_line − delta| = 11.6319 °. This is larger than the requested numerical tolerance.
  5. Invert both limits Y_out = 1.3251921 |g| and 1.4994561 |g|. Sort the roots even if the response decreases: 131.433 ° ≤ delta ≤ 138.502 °.
  6. The lower and upper input deviations are 3.64333 ° and 3.42534 °. They differ because the inverse response is nonlinear; a symmetric error bar would only be a local approximation. This interval includes reading uncertainty only, not model error or uncertainty in fixed inputs.

Answer delta ≈ 135.076 °; compatible interval [131.433, 138.502] °. Endpoint interpolation gives 123.445 °.

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.