University Quantum Field Theory I · topic UQFTI-12.02
Renormalised QED: Z_1, Z_2, Z_3, delta m and the on-shell conditions
Connect the ideas, make your working visible, and test the result. Use the hints when you need a starting point; open the full solution after your attempt.
Further practice
Work through a fresh case before tackling the extension.
Renormalised QED: Z₁, Z₂, Z₃, δₘ and on-shell conditions: predict a finite change
A QED renormalisation condition defines a measured quantity and so fixes one counterterm: the electron propagator has its pole at the measured mass with residue 1, the photon propagator has residue 1 at q² = 0, and the vertex equals γ^μ at zero momentum transfer. Use the supplied topic model Y_out = 137.036*(1-0.0035657*uv), where Y_out is BARE 1/α₀ (dimensionless). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793. uv is Regulator mass, log₁₀(Λ/m), dimensionless. Keep ir (Photon mass, log₁₀(m/λ)) = 9 fixed. For this exercise use only 2 ≤ uv ≤ 22, at the specified test settings separated by 1. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. Calculate Y_out at uv = 6 and 7. Find the signed output change ΔY_out and the average sensitivity ΔY_out/Δuv across this interval. State whether the response increases or decreases; explain why a finite difference between these settings does not require interpolation between them.
BARE 1/α₀ against uv
Predictions from the supplied Renormalised QED: Z₁, Z₂, Z₃, δₘ and on-shell conditions model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.
Vertical axis (y): BARE 1/α₀
Horizontal axis (x): uv: Regulator mass, log₁₀(Λ/m)
Axes show the supplied calibration interval; the origin may lie outside the plot.
Read the exact data as a table
| uv: Regulator mass, log₁₀(Λ/m) | BARE 1/α₀ |
|---|---|
| 2 | 136.0587414696 |
| 7 | 133.6155951436 |
| 12 | 131.17244881759999 |
| 17 | 128.7293024916 |
| 22 | 126.2861561656 |
These are the supplied values, not a worked answer. No fitted trend is drawn.
Show a hint
Substitute each value of uv separately while keeping every other input fixed, then subtract in the same order.
Reveal the worked solution
- At uv = 6, substitute into Y_out = 137.036*(1-0.0035657*uv): Y₀ = 134.104.
- At uv = 7, the same fixed-parameter model gives Y₁ = 133.616.
- Signed change: ΔY_out = Y₁ − Y₀ = -0.488629; the input change is Δuv = 1.
- Average sensitivity is ΔY_out/Δuv = -0.488629 1 per unit input. Its negative sign means that this response decreases over the specified interval.
- This finite difference compares two specified test settings without interpolating between them. A point derivative is not required. Any quantum numbers or particle counts must also obey their physical admissibility conditions.
Answer Y₀ = 134.104, Y₁ = 133.616; ΔY_out = -0.488629; average sensitivity = -0.488629 1 per unit input.
Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.
Extra challenging questions
Work through the linked stages and explain what each result means.
Renormalised QED: Z₁, Z₂, Z₃, δₘ and on-shell conditions: infer an input with uncertainty
A QED renormalisation condition defines a measured quantity and so fixes one counterterm: the electron propagator has its pole at the measured mass with residue 1, the photon propagator has residue 1 at q² = 0, and the vertex equals γ^μ at zero momentum transfer. Use the supplied topic model Y_out = 137.036*(1-0.0035657*uv), where Y_out is BARE 1/α₀ (dimensionless). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793. uv is Regulator mass, log₁₀(Λ/m), dimensionless. Keep ir (Photon mass, log₁₀(m/λ)) = 9 fixed. For this exercise use only 2 ≤ uv ≤ 22, at the specified test settings separated by 1. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. A reading gives Y_out = 130.19519, with a bounded reading uncertainty ±0.78181. Treat the model and all fixed inputs as exact for this exercise; the bound is not a standard deviation. Determine every allowed value of uv consistent with that bound. Compare with a straight-line interpolation between the two endpoint predictions, and explain why a fractional setting may be inadmissible. Do not assume that the supplied calibration points prove monotonicity outside this branch.
BARE 1/α₀ against uv
Predictions from the supplied Renormalised QED: Z₁, Z₂, Z₃, δₘ and on-shell conditions model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.
Vertical axis (y): BARE 1/α₀
Horizontal axis (x): uv: Regulator mass, log₁₀(Λ/m)
Axes show the supplied calibration interval; the origin may lie outside the plot.
Read the exact data as a table
| uv: Regulator mass, log₁₀(Λ/m) | BARE 1/α₀ |
|---|---|
| 2 | 136.0587414696 |
| 7 | 133.6155951436 |
| 12 | 131.17244881759999 |
| 17 | 128.7293024916 |
| 22 | 126.2861561656 |
These are the supplied values, not a worked answer. No fitted trend is drawn.
Show a hint
Enumerate the permitted settings in the stated range, evaluate Y_out at each, and retain every setting satisfying |Y_out − Y_measured| ≤ u. The plotted predictions are supplied calibration evidence.
Reveal the worked solution
- Endpoint predictions are Y_out(2) = 136.059 and Y_out(22) = 126.286. The target lies between them. On the selected branch the response is strictly decreasing.
- Endpoint interpolation gives uv_line = 2 + (130.195 − 136.059)(22 − 2)/(126.286 − 136.059) = 14. This estimates the inverse of the endpoint chord, rather than assuming that chord is the physical model.
- Evaluate the model at each permitted setting. The central reading corresponds to uv = 14; only the allowed settings 13, 14, 15 lie inside the stated reading bound.
- The interpolation error in the input is |uv_line − uv| = 5.87767e-7.
- The compatible allowed values span 13 to 15. Values between specified test settings are outside this exercise's input domain even if an interpolation passes through them.
- The quoted output bound restricts which specified settings remain compatible. It does not change physical restrictions on quantum numbers or counts, and the chosen grid alone does not establish physical quantisation.
Answer Compatible uv: 13, 14, 15. Endpoint interpolation predicts 14; check admissibility against the discrete settings.
Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.