Skip to main content
Course and syllabus guidance

University Quantum Field Theory I · topic UQFTI-12.09

The photon self-energy is transverse, so the photon stays massless

Connect the ideas, make your working visible, and test the result. Use the hints when you need a starting point; open the full solution after your attempt.

Further practice

Work through a fresh case before tackling the extension.

Further practice · 01

A transverse self-energy keeps the photon massless: predict a finite change

The photon self-energy Π^μν(q) obeys q_μΠ^μν = 0, so it equals (q²g^μν − q^μq^ν)Π(q²); the factor q² lets it rescale the photon propagator by Z₃ = 1/(1 − Π(0)) but never move its pole from q² = 0. Use the supplied topic model Y_out = sqrt(2*a/((1-p0)+sqrt((1-p0)^2-4*s*a))), where Y_out is PHOTON MASS (mₑ). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793; sqrt(x) means √x. a is Non-transverse piece a, measured in mₑ². Keep p0 (Π(0), the self-energy at q² = 0) = -0.08; s (Slope s, in Π(q²) = Π(0) + s q²/mₑ²) = -0.1 fixed. For this exercise use only 0.053125 mₑ² ≤ a ≤ 0.446875 mₑ² on this continuous branch. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. Calculate Y_out at a = 0.13975 mₑ² and 0.194875 mₑ². Find the signed output change ΔY_out and the average sensitivity ΔY_out/Δa across this interval. State whether the response increases or decreases; distinguish this interval average from a derivative at one point.

Explore the question data

PHOTON MASS against a

Predictions from the supplied A transverse self-energy keeps the photon massless model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.

Vertical axis (y): PHOTON MASS / mₑ

PHOTON MASS against aPredictions from the supplied A transverse self-energy keeps the photon massless model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law. Horizontal axis: a: Non-transverse piece a / mₑ². Vertical axis: PHOTON MASS / mₑ. Exact values are available in the data table below.0.20490.31570.42650.53730.64810.037370.14370.250.35630.4626xy

Horizontal axis (x): a: Non-transverse piece a / mₑ²

Axes show the supplied calibration interval; the origin may lie outside the plot.

Reading 1a: Non-transverse piece a / mₑ²: 0.05312PHOTON MASS / mₑ: 0.2213
Read the exact data as a table
PHOTON MASS against a — supplied values
a: Non-transverse piece a / mₑ²PHOTON MASS / mₑ
0.0531250.22128667415882272
0.15156250.37223383152899087
0.250.47615329323032035
0.348437499999999960.5599335845349833
0.446874999999999970.6316882865124185

These are the supplied values, not a worked answer. No fitted trend is drawn.

Show a hint

Substitute each value of a separately while keeping every other input fixed, then subtract in the same order.

Reveal the worked solution
  1. At a = 0.13975 mₑ², substitute into Y_out = sqrt(2*a/((1-p0)+sqrt((1-p0)^2-4*s*a))): Y₀ = 0.357609 mₑ.
  2. At a = 0.194875 mₑ², the same fixed-parameter model gives Y₁ = 0.421333 mₑ.
  3. Signed change: ΔY_out = Y₁ − Y₀ = 0.0637249 mₑ; the input change is Δa = 0.055125 mₑ².
  4. Average sensitivity is ΔY_out/Δa = 1.15601 mₑ per mₑ². Its positive sign means that this response increases over the specified interval.
  5. This is a secant slope between two settings. It equals a point derivative only for a locally linear relation or in a justified small-interval limit.

Answer Y₀ = 0.357609 mₑ, Y₁ = 0.421333 mₑ; ΔY_out = 0.0637249 mₑ; average sensitivity = 1.15601 mₑ per mₑ².

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.

Extra challenging questions

Work through the linked stages and explain what each result means.

Extra challenging · 01

A transverse self-energy keeps the photon massless: infer an input with uncertainty

The photon self-energy Π^μν(q) obeys q_μΠ^μν = 0, so it equals (q²g^μν − q^μq^ν)Π(q²); the factor q² lets it rescale the photon propagator by Z₃ = 1/(1 − Π(0)) but never move its pole from q² = 0. Use the supplied topic model Y_out = sqrt(2*a/((1-p0)+sqrt((1-p0)^2-4*s*a))), where Y_out is PHOTON MASS (mₑ). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793; sqrt(x) means √x. a is Non-transverse piece a, measured in mₑ². Keep p0 (Π(0), the self-energy at q² = 0) = -0.08; s (Slope s, in Π(q²) = Π(0) + s q²/mₑ²) = -0.1 fixed. For this exercise use only 0.053125 mₑ² ≤ a ≤ 0.446875 mₑ² on this continuous branch. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. A reading gives Y_out = 0.51485865 mₑ, with a bounded reading uncertainty ±0.017524 mₑ. Treat the model and all fixed inputs as exact for this exercise; the bound is not a standard deviation. First estimate the unknown a by straight-line interpolation between the two endpoint predictions. Then solve the actual model on the stated branch to an absolute input tolerance of 0.000039375 mₑ², using a numerical bracket if required. Find the full input interval consistent with the bounded reading uncertainty and compare it with a symmetric input-error assumption. Do not assume that the supplied calibration points prove monotonicity outside this branch.

Explore the question data

PHOTON MASS against a

Predictions from the supplied A transverse self-energy keeps the photon massless model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.

Vertical axis (y): PHOTON MASS / mₑ

PHOTON MASS against aPredictions from the supplied A transverse self-energy keeps the photon massless model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law. Horizontal axis: a: Non-transverse piece a / mₑ². Vertical axis: PHOTON MASS / mₑ. Exact values are available in the data table below.0.20490.31570.42650.53730.64810.037370.14370.250.35630.4626xy

Horizontal axis (x): a: Non-transverse piece a / mₑ²

Axes show the supplied calibration interval; the origin may lie outside the plot.

Reading 1a: Non-transverse piece a / mₑ²: 0.05312PHOTON MASS / mₑ: 0.2213
Read the exact data as a table
PHOTON MASS against a — supplied values
a: Non-transverse piece a / mₑ²PHOTON MASS / mₑ
0.0531250.22128667415882272
0.15156250.37223383152899087
0.250.47615329323032035
0.348437499999999960.5599335845349833
0.446874999999999970.6316882865124185

These are the supplied values, not a worked answer. No fitted trend is drawn.

Show a hint

The model's endpoint predictions bracket the reading. Solve Y_out(a) = Y_measured and then solve again at Y_measured − u and Y_measured + u; a nonlinear inverse can give unequal input deviations.

Reveal the worked solution
  1. Endpoint predictions are Y_out(0.053125) = 0.221287 mₑ and Y_out(0.446875) = 0.631688 mₑ. The target lies between them. On the selected branch the response is strictly increasing.
  2. Endpoint interpolation gives a_line = 0.053125 + (0.514859 − 0.221287)(0.446875 − 0.053125)/(0.631688 − 0.221287) = 0.334786 mₑ². This estimates the inverse of the endpoint chord, rather than assuming that chord is the physical model.
  3. Use the actual equation, not the chord, and bracket its root. Evaluating the midpoint and retaining the sign-changing half-interval gives a = 0.293312 mₑ²; substituting back gives Y_out = 0.51485865 mₑ.
  4. The interpolation error in the input is |a_line − a| = 0.0414731 mₑ². This is larger than the requested numerical tolerance.
  5. Invert both limits Y_out = 0.49733465 mₑ and 0.53238265 mₑ. Sort the roots even if the response decreases: 0.273247 mₑ² ≤ a ≤ 0.314139 mₑ².
  6. The lower and upper input deviations are 0.0200656 mₑ² and 0.0208266 mₑ². They differ because the inverse response is nonlinear; a symmetric error bar would only be a local approximation. This interval includes reading uncertainty only, not model error or uncertainty in fixed inputs.

Answer a ≈ 0.293312 mₑ²; compatible interval [0.273247, 0.314139] mₑ². Endpoint interpolation gives 0.334786 mₑ².

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.