The three Pauli matrices

Connect the ideas, make your working visible, and test the result. Use the hints when you need a starting point; open the full solution after your attempt.

Further practice

Work through a fresh case before tackling the extension.

Further practice · 01

The three Pauli matrices: predict a finite change

The Pauli matrices σₓ, σ_y and σ_z are the three 2×2 Hermitian, traceless matrices that represent the x, y and z components of spin-½ in units of ħ/2, written in the basis |+z⟩, |−z⟩. Use the supplied topic model Y_out = (1000*cosd(beta-alpha))/1000, where Y_out is I PART a⋅b (before display rounding) (dimensionless). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793; sind/cosd/tand use degrees. alpha is Axis a (solid), α from +z, measured in °. Keep beta (Axis b (dashed), β from +z) = 60 ° fixed. For this exercise use only 246.15 ° ≤ alpha ≤ 321.75 ° on this continuous branch. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. Calculate Y_out at alpha = 262.782 ° and 273.366 °. Find the signed output change ΔY_out and the average sensitivity ΔY_out/Δalpha across this interval. State whether the response increases or decreases; distinguish this interval average from a derivative at one point.

Explore the question data

I PART a⋅b (before display rounding) against alpha

Predictions from the supplied The three Pauli matrices model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.

Vertical axis (y): I PART a⋅b (before display rounding)

I PART a⋅b (before display rounding) against alphaPredictions from the supplied The three Pauli matrices model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law. Horizontal axis: alpha: Axis a (solid), α from +z / °. Vertical axis: I PART a⋅b (before display rounding). Exact values are available in the data table below.-1.028-0.7986-0.5689-0.3392-0.1095243.1263.5283.9304.4324.8xy

Horizontal axis (x): alpha: Axis a (solid), α from +z / °

Axes show the supplied calibration interval; the origin may lie outside the plot.

Reading 1alpha: Axis a (solid), α from +z / °: 246.1I PART a⋅b (before display rounding): -0.9942
Read the exact data as a table
I PART a⋅b (before display rounding) against alpha — supplied values
alpha: Axis a (solid), α from +z / °I PART a⋅b (before display rounding)
246.14999999999998-0.9942448326331055
265.04999999999995-0.9059386379797364
283.95-0.7199457301444867
302.85-0.45632159090047586
321.75-0.1434926219911794

These are the supplied values, not a worked answer. No fitted trend is drawn.

Show a hint

Substitute each value of alpha separately while keeping every other input fixed, then subtract in the same order.

Reveal the worked solution
  1. At alpha = 262.782 °, substitute into Y_out = (1000*cosd(beta-alpha))/1000: Y₀ = -0.921985.
  2. At alpha = 273.366 °, the same fixed-parameter model gives Y₁ = -0.835174.
  3. Signed change: ΔY_out = Y₁ − Y₀ = 0.0868105; the input change is Δalpha = 10.584 °.
  4. Average sensitivity is ΔY_out/Δalpha = 0.00820205 1 per °. Its positive sign means that this response increases over the specified interval.
  5. This is a secant slope between two settings. It equals a point derivative only for a locally linear relation or in a justified small-interval limit.

Answer Y₀ = -0.921985, Y₁ = -0.835174; ΔY_out = 0.0868105; average sensitivity = 0.00820205 1 per °.

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.

Extra challenging questions

Work through the linked stages and explain what each result means.

Extra challenging · 01

The three Pauli matrices: infer an input with uncertainty

The Pauli matrices σₓ, σ_y and σ_z are the three 2×2 Hermitian, traceless matrices that represent the x, y and z components of spin-½ in units of ħ/2, written in the basis |+z⟩, |−z⟩. Use the supplied topic model Y_out = (1000*cosd(beta-alpha))/1000, where Y_out is I PART a⋅b (before display rounding) (dimensionless). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793; sind/cosd/tand use degrees. alpha is Axis a (solid), α from +z, measured in °. Keep beta (Axis b (dashed), β from +z) = 60 ° fixed. For this exercise use only 246.15 ° ≤ alpha ≤ 321.75 ° on this continuous branch. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. A reading gives Y_out = -0.61199645, with a bounded reading uncertainty ±0.057337. Treat the model and all fixed inputs as exact for this exercise; the bound is not a standard deviation. First estimate the unknown alpha by straight-line interpolation between the two endpoint predictions. Then solve the actual model on the stated branch to an absolute input tolerance of 0.00756 °, using a numerical bracket if required. Find the full input interval consistent with the bounded reading uncertainty and compare it with a symmetric input-error assumption. Do not assume that the supplied calibration points prove monotonicity outside this branch.

Explore the question data

I PART a⋅b (before display rounding) against alpha

Predictions from the supplied The three Pauli matrices model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.

Vertical axis (y): I PART a⋅b (before display rounding)

I PART a⋅b (before display rounding) against alphaPredictions from the supplied The three Pauli matrices model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law. Horizontal axis: alpha: Axis a (solid), α from +z / °. Vertical axis: I PART a⋅b (before display rounding). Exact values are available in the data table below.-1.028-0.7986-0.5689-0.3392-0.1095243.1263.5283.9304.4324.8xy

Horizontal axis (x): alpha: Axis a (solid), α from +z / °

Axes show the supplied calibration interval; the origin may lie outside the plot.

Reading 1alpha: Axis a (solid), α from +z / °: 246.1I PART a⋅b (before display rounding): -0.9942
Read the exact data as a table
I PART a⋅b (before display rounding) against alpha — supplied values
alpha: Axis a (solid), α from +z / °I PART a⋅b (before display rounding)
246.14999999999998-0.9942448326331055
265.04999999999995-0.9059386379797364
283.95-0.7199457301444867
302.85-0.45632159090047586
321.75-0.1434926219911794

These are the supplied values, not a worked answer. No fitted trend is drawn.

Show a hint

The model's endpoint predictions bracket the reading. Solve Y_out(alpha) = Y_measured and then solve again at Y_measured − u and Y_measured + u; a nonlinear inverse can give unequal input deviations.

Reveal the worked solution
  1. Endpoint predictions are Y_out(246.15) = -0.994245 and Y_out(321.75) = -0.143493. The target lies between them. On the selected branch the response is strictly increasing.
  2. Endpoint interpolation gives alpha_line = 246.15 + (-0.611996 − -0.994245)(321.75 − 246.15)/(-0.143493 − -0.994245) = 280.118 °. This estimates the inverse of the endpoint chord, rather than assuming that chord is the physical model.
  3. Use the actual equation, not the chord, and bracket its root. Evaluating the midpoint and retaining the sign-changing half-interval gives alpha = 292.266 °; substituting back gives Y_out = -0.61199645.
  4. The interpolation error in the input is |alpha_line − alpha| = 12.1484 °. This is larger than the requested numerical tolerance.
  5. Invert both limits Y_out = -0.66933345 and -0.55465945. Sort the roots even if the response decreases: 287.984 ° ≤ alpha ≤ 296.313 °.
  6. The lower and upper input deviations are 4.28164 ° and 4.04674 °. They differ because the inverse response is nonlinear; a symmetric error bar would only be a local approximation. This interval includes reading uncertainty only, not model error or uncertainty in fixed inputs.

Answer alpha ≈ 292.266 °; compatible interval [287.984, 296.313] °. Endpoint interpolation gives 280.118 °.

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.