Skip to main content
Course and syllabus guidance

MYP Physics · topic MYP-12.05

X-ray imaging: benefit and exposure

Connect the ideas, make your working visible, and test the result. Use the hints when you need a starting point; open the full solution after your attempt.

Extra challenging questions

Work through the linked stages and explain what each result means.

Extra challenging · 01

A sharper X-ray image with a dose trade-off

Optional enrichment: this challenge may extend beyond the usual syllabus depth and assumes confidence with algebra and graph interpretation. An X-ray beam passes through a uniform absorber. Measured transmitted intensity fractions are supplied. Assume exponential attenuation I/I0 = exp(−μx), ignore scatter, and use h = 6.63×10⁻³⁴ J s, c = 3.0×10⁸ m s⁻¹ and electron charge e = 1.60×10⁻¹⁹ C. The tube voltage is 60 kV. Supplied model: For the shortest X-ray wavelength use eV = hc/λmin. Supplied data (Thickness / cm; I/I₀): (0, 1), (1, 0.5), (2, 0.25), (3, 0.125). (a) Determine attenuation coefficient, transmission through 4 cm and the shortest possible tube-emission wavelength. [3 marks] (b) Explain the image contrast and evaluate raising beam intensity to improve a weak image. [3 marks]

Explore the question data

Measured X-ray attenuation

Supplied question data. Read the labelled axes and use the observations to test the physical model.

Vertical axis (y): I/I₀

Measured X-ray attenuationSupplied question data. Read the labelled axes and use the observations to test the physical model. Horizontal axis: Thickness / cm. Vertical axis: I/I₀. Exact values are available in the data table below.00.250.50.75100.751.52.253xy

Horizontal axis (x): Thickness / cm

Reading 1Thickness / cm: 0I/I₀: 1
Read the exact data as a table
Measured X-ray attenuation — supplied values
Thickness / cmI/I₀
01
10.5
20.25
30.125

These are the supplied values, not a worked answer. Lines join the supplied values; they are not a fitted model.

Show a hint

Begin with part (a): Determine attenuation coefficient, transmission through 4 cm and the shortest possible tube-emission wavelength.

Reveal the worked solution
  1. The half-value thickness is 0.01 m, so μ = ln2/0.01 ≈69.3 m⁻¹. Four such thicknesses transmit (1/2)⁴ = 1/16.
  2. The greatest photon energy is the full electron energy eV = (1.60×10⁻¹⁹)(60000) = 9.60×10⁻¹⁵ J.
  3. Using E = hc/λ gives λmin = hc/(eV) ≈2.07×10⁻¹¹ m. Most emitted photons need not have this maximum energy.
  4. Different tissue thicknesses and attenuation coefficients give different transmitted intensities at the detector, creating contrast.
  5. If detected photons are independently counted, relative random counting uncertainty scales approximately as 1/√N; increasing N can improve statistical image quality.
  6. X-rays are ionising, so increased photon fluence can increase patient dose. The exposure should be justified by the diagnostic task, with collimation, shielding and detector efficiency considered; ultrasound may answer some questions without ionising radiation.

Answer (a) μ≈69.3 m⁻¹; transmission at 4 cm = 1/16 = 6.25%; λmin≈2.07×10⁻¹¹ m. (b) Different attenuation gives contrast; more incident photons can reduce relative counting noise but also increases exposure.

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.

Open full question workspace and marking guide →

Keep practising