Skip to main content
Course and syllabus guidance

University Advanced Quantum Mechanics · topic UAQM-14.01

Reduced dynamics and the Kraus representation

Connect the ideas, make your working visible, and test the result. Use the hints when you need a starting point; open the full solution after your attempt.

Further practice

Work through a fresh case before tackling the extension.

Further practice · 01

Reduced dynamics and the Kraus representation: predict a finite change

The Kraus representation writes the evolution of a system that shares a unitary with an environment as ρ → Σₖ Kₖ ρ Kₖ†, a sum of operators acting on the system alone whose only constraint is Σₖ Kₖ†Kₖ = 1. Use the supplied topic model Y_out = 0.5*(1+(cosd(th)^2*cosd(a)+sind(th)^2*(2*p-1))^2+cosd(th)^2*sind(a)^2), where Y_out is PURITY Tr ρ_S² (dimensionless). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793; sind/cosd/tand use degrees. a is Initial Bloch angle α of S, measured in °. Keep p (Excitation probability p of E) = 0; th (Coupling angle gt) = 45 ° fixed. For this exercise use only 19.125 ° ≤ a ≤ 160.875 ° on this continuous branch. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. Calculate Y_out at a = 50.31 ° and 70.155 °. Find the signed output change ΔY_out and the average sensitivity ΔY_out/Δa across this interval. State whether the response increases or decreases; distinguish this interval average from a derivative at one point.

Explore the question data

PURITY Tr ρ_S² against a

Predictions from the supplied Reduced dynamics and the Kraus representation model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.

Vertical axis (y): PURITY Tr ρ_S²

PURITY Tr ρ_S² against aPredictions from the supplied Reduced dynamics and the Kraus representation model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law. Horizontal axis: a: Initial Bloch angle α of S / °. Vertical axis: PURITY Tr ρ_S². Exact values are available in the data table below.0.50830.63590.76340.8911.01913.4651.7390128.3166.5xy

Horizontal axis (x): a: Initial Bloch angle α of S / °

Axes show the supplied calibration interval; the origin may lie outside the plot.

Reading 1a: Initial Bloch angle α of S / °: 19.13PURITY Tr ρ_S²: 0.5272
Read the exact data as a table
PURITY Tr ρ_S² against a — supplied values
a: Initial Bloch angle α of S / °PURITY Tr ρ_S²
19.1250.5272161802032339
54.56250.6880232491909773
900.875
125.43750.9779305232542341
160.8750.9996192034366729

These are the supplied values, not a worked answer. No fitted trend is drawn.

Show a hint

Substitute each value of a separately while keeping every other input fixed, then subtract in the same order.

Reveal the worked solution
  1. At a = 50.31 °, substitute into Y_out = 0.5*(1+(cosd(th)^2*cosd(a)+sind(th)^2*(2*p-1))^2+cosd(th)^2*sind(a)^2): Y₀ = 0.66436.
  2. At a = 70.155 °, the same fixed-parameter model gives Y₁ = 0.775725.
  3. Signed change: ΔY_out = Y₁ − Y₀ = 0.111365; the input change is Δa = 19.845 °.
  4. Average sensitivity is ΔY_out/Δa = 0.00561175 1 per °. Its positive sign means that this response increases over the specified interval.
  5. This is a secant slope between two settings. It equals a point derivative only for a locally linear relation or in a justified small-interval limit.

Answer Y₀ = 0.66436, Y₁ = 0.775725; ΔY_out = 0.111365; average sensitivity = 0.00561175 1 per °.

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.

Extra challenging questions

Work through the linked stages and explain what each result means.

Extra challenging · 01

Reduced dynamics and the Kraus representation: infer an input with uncertainty

The Kraus representation writes the evolution of a system that shares a unitary with an environment as ρ → Σₖ Kₖ ρ Kₖ†, a sum of operators acting on the system alone whose only constraint is Σₖ Kₖ†Kₖ = 1. Use the supplied topic model Y_out = 0.5*(1+(cosd(th)^2*cosd(a)+sind(th)^2*(2*p-1))^2+cosd(th)^2*sind(a)^2), where Y_out is PURITY Tr ρ_S² (dimensionless). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793; sind/cosd/tand use degrees. a is Initial Bloch angle α of S, measured in °. Keep p (Excitation probability p of E) = 0; th (Coupling angle gt) = 45 ° fixed. For this exercise use only 19.125 ° ≤ a ≤ 160.875 ° on this continuous branch. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. A reading gives Y_out = 0.93316718, with a bounded reading uncertainty ±0.0099678. Treat the model and all fixed inputs as exact for this exercise; the bound is not a standard deviation. First estimate the unknown a by straight-line interpolation between the two endpoint predictions. Then solve the actual model on the stated branch to an absolute input tolerance of 0.014175 °, using a numerical bracket if required. Find the full input interval consistent with the bounded reading uncertainty and compare it with a symmetric input-error assumption. Do not assume that the supplied calibration points prove monotonicity outside this branch.

Explore the question data

PURITY Tr ρ_S² against a

Predictions from the supplied Reduced dynamics and the Kraus representation model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.

Vertical axis (y): PURITY Tr ρ_S²

PURITY Tr ρ_S² against aPredictions from the supplied Reduced dynamics and the Kraus representation model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law. Horizontal axis: a: Initial Bloch angle α of S / °. Vertical axis: PURITY Tr ρ_S². Exact values are available in the data table below.0.50830.63590.76340.8911.01913.4651.7390128.3166.5xy

Horizontal axis (x): a: Initial Bloch angle α of S / °

Axes show the supplied calibration interval; the origin may lie outside the plot.

Reading 1a: Initial Bloch angle α of S / °: 19.13PURITY Tr ρ_S²: 0.5272
Read the exact data as a table
PURITY Tr ρ_S² against a — supplied values
a: Initial Bloch angle α of S / °PURITY Tr ρ_S²
19.1250.5272161802032339
54.56250.6880232491909773
900.875
125.43750.9779305232542341
160.8750.9996192034366729

These are the supplied values, not a worked answer. No fitted trend is drawn.

Show a hint

The model's endpoint predictions bracket the reading. Solve Y_out(a) = Y_measured and then solve again at Y_measured − u and Y_measured + u; a nonlinear inverse can give unequal input deviations.

Reveal the worked solution
  1. Endpoint predictions are Y_out(19.125) = 0.527216 and Y_out(160.875) = 0.999619. The target lies between them. On the selected branch the response is strictly increasing.
  2. Endpoint interpolation gives a_line = 19.125 + (0.933167 − 0.527216)(160.875 − 19.125)/(0.999619 − 0.527216) = 140.935 °. This estimates the inverse of the endpoint chord, rather than assuming that chord is the physical model.
  3. Use the actual equation, not the chord, and bracket its root. Evaluating the midpoint and retaining the sign-changing half-interval gives a = 105.593 °; substituting back gives Y_out = 0.93316718.
  4. The interpolation error in the input is |a_line − a| = 35.3428 °. This is larger than the requested numerical tolerance.
  5. Invert both limits Y_out = 0.92319938 and 0.94313498. Sort the roots even if the response decreases: 102.484 ° ≤ a ≤ 108.997 °.
  6. The lower and upper input deviations are 3.1089 ° and 3.40472 °. They differ because the inverse response is nonlinear; a symmetric error bar would only be a local approximation. This interval includes reading uncertainty only, not model error or uncertainty in fixed inputs.

Answer a ≈ 105.593 °; compatible interval [102.484, 108.997] °. Endpoint interpolation gives 140.935 °.

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.