Skip to main content
Course and syllabus guidance

University Quantum Mechanics II · topic UQMII-05.02

Rotating a spin-half, and the sign change under 2 pi

Connect the ideas, make your working visible, and test the result. Use the hints when you need a starting point; open the full solution after your attempt.

Further practice

Work through a fresh case before tackling the extension.

Further practice · 01

Rotating a spin-half, and the sign change under 2π: predict a finite change

The spin-½ rotation operator D(n̂, φ) = cos(φ/2) I − i sin(φ/2) σ⋅n̂ is the 2 × 2 unitary matrix that turns a spinor through the angle φ about the unit axis n̂; it rotates ⟨S⟩ through φ, yet equals −I, not I, at φ = 2π. Use the supplied topic model Y_out = (1+cos(phi*pi/360))/2, where Y_out is FRINGE I/I₀ (dimensionless). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793; unmarked trigonometric functions use radians. phi is Rotation angle φ, measured in °. Keep theta (Spin tilt from axis θ) = 60 ° fixed. For this exercise use only 378.9 ° ≤ phi ≤ 643.5 ° on this continuous branch. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. Calculate Y_out at phi = 437.112 ° and 474.156 °. Find the signed output change ΔY_out and the average sensitivity ΔY_out/Δphi across this interval. State whether the response increases or decreases; distinguish this interval average from a derivative at one point.

Explore the question data

FRINGE I/I₀ against phi

Predictions from the supplied Rotating a spin-half, and the sign change under 2π model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.

Vertical axis (y): FRINGE I/I₀

FRINGE I/I₀ against phiPredictions from the supplied Rotating a spin-half, and the sign change under 2π model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law. Horizontal axis: phi: Rotation angle φ / °. Vertical axis: FRINGE I/I₀. Exact values are available in the data table below.-0.028650.21050.44970.68890.9281368.3439.8511.2582.6654.1xy

Horizontal axis (x): phi: Rotation angle φ / °

Axes show the supplied calibration interval; the origin may lie outside the plot.

Reading 1phi: Rotation angle φ / °: 378.9FRINGE I/I₀: 0.006785
Read the exact data as a table
FRINGE I/I₀ against phi — supplied values
phi: Rotation angle φ / °FRINGE I/I₀
378.90.006785371411752228
445.049999999999950.13150875760102443
511.20.37565505641757235
577.350.6600998308136561
643.50.8926584654403723

These are the supplied values, not a worked answer. No fitted trend is drawn.

Show a hint

Substitute each value of phi separately while keeping every other input fixed, then subtract in the same order.

Reveal the worked solution
  1. At phi = 437.112 °, substitute into Y_out = (1+cos(phi*pi/360))/2: Y₀ = 0.109.
  2. At phi = 474.156 °, the same fixed-parameter model gives Y₁ = 0.228252.
  3. Signed change: ΔY_out = Y₁ − Y₀ = 0.119251; the input change is Δphi = 37.044 °.
  4. Average sensitivity is ΔY_out/Δphi = 0.00321918 1 per °. Its positive sign means that this response increases over the specified interval.
  5. This is a secant slope between two settings. It equals a point derivative only for a locally linear relation or in a justified small-interval limit.

Answer Y₀ = 0.109, Y₁ = 0.228252; ΔY_out = 0.119251; average sensitivity = 0.00321918 1 per °.

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.

Extra challenging questions

Work through the linked stages and explain what each result means.

Extra challenging · 01

Rotating a spin-half, and the sign change under 2π: infer an input with uncertainty

The spin-½ rotation operator D(n̂, φ) = cos(φ/2) I − i sin(φ/2) σ⋅n̂ is the 2 × 2 unitary matrix that turns a spinor through the angle φ about the unit axis n̂; it rotates ⟨S⟩ through φ, yet equals −I, not I, at φ = 2π. Use the supplied topic model Y_out = (1+cos(phi*pi/360))/2, where Y_out is FRINGE I/I₀ (dimensionless). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793; unmarked trigonometric functions use radians. phi is Rotation angle φ, measured in °. Keep theta (Spin tilt from axis θ) = 60 ° fixed. For this exercise use only 378.9 ° ≤ phi ≤ 643.5 ° on this continuous branch. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. A reading gives Y_out = 0.50133518, with a bounded reading uncertainty ±0.058698. Treat the model and all fixed inputs as exact for this exercise; the bound is not a standard deviation. First estimate the unknown phi by straight-line interpolation between the two endpoint predictions. Then solve the actual model on the stated branch to an absolute input tolerance of 0.02646 °, using a numerical bracket if required. Find the full input interval consistent with the bounded reading uncertainty and compare it with a symmetric input-error assumption. Do not assume that the supplied calibration points prove monotonicity outside this branch.

Explore the question data

FRINGE I/I₀ against phi

Predictions from the supplied Rotating a spin-half, and the sign change under 2π model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.

Vertical axis (y): FRINGE I/I₀

FRINGE I/I₀ against phiPredictions from the supplied Rotating a spin-half, and the sign change under 2π model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law. Horizontal axis: phi: Rotation angle φ / °. Vertical axis: FRINGE I/I₀. Exact values are available in the data table below.-0.028650.21050.44970.68890.9281368.3439.8511.2582.6654.1xy

Horizontal axis (x): phi: Rotation angle φ / °

Axes show the supplied calibration interval; the origin may lie outside the plot.

Reading 1phi: Rotation angle φ / °: 378.9FRINGE I/I₀: 0.006785
Read the exact data as a table
FRINGE I/I₀ against phi — supplied values
phi: Rotation angle φ / °FRINGE I/I₀
378.90.006785371411752228
445.049999999999950.13150875760102443
511.20.37565505641757235
577.350.6600998308136561
643.50.8926584654403723

These are the supplied values, not a worked answer. No fitted trend is drawn.

Show a hint

The model's endpoint predictions bracket the reading. Solve Y_out(phi) = Y_measured and then solve again at Y_measured − u and Y_measured + u; a nonlinear inverse can give unequal input deviations.

Reveal the worked solution
  1. Endpoint predictions are Y_out(378.9) = 0.00678537 and Y_out(643.5) = 0.892658. The target lies between them. On the selected branch the response is strictly increasing.
  2. Endpoint interpolation gives phi_line = 378.9 + (0.501335 − 0.00678537)(643.5 − 378.9)/(0.892658 − 0.00678537) = 526.616 °. This estimates the inverse of the endpoint chord, rather than assuming that chord is the physical model.
  3. Use the actual equation, not the chord, and bracket its root. Evaluating the midpoint and retaining the sign-changing half-interval gives phi = 540.306 °; substituting back gives Y_out = 0.50133518.
  4. The interpolation error in the input is |phi_line − phi| = 13.6897 °. This is larger than the requested numerical tolerance.
  5. Invert both limits Y_out = 0.44263718 and 0.56003318. Sort the roots even if the response decreases: 526.824 ° ≤ phi ≤ 553.792 °.
  6. The lower and upper input deviations are 13.4816 ° and 13.4859 °. They differ because the inverse response is nonlinear; a symmetric error bar would only be a local approximation. This interval includes reading uncertainty only, not model error or uncertainty in fixed inputs.

Answer phi ≈ 540.306 °; compatible interval [526.824, 553.792] °. Endpoint interpolation gives 526.616 °.

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.