Skip to main content
Course and syllabus guidance

University Quantum Mechanics II · topic UQMII-05.05

The allowed values of j, from |j_1 - j_2| to j_1 + j_2

Connect the ideas, make your working visible, and test the result. Use the hints when you need a starting point; open the full solution after your attempt.

Further practice

Work through a fresh case before tackling the extension.

Further practice · 01

The allowed values of j, from |j₁ − j₂| to j₁ + j₂: predict a finite change

Coupling angular momenta j₁ and j₂ produces exactly one multiplet of total angular momentum j for each j = |j₁ − j₂|, |j₁ − j₂| + 1, …, j₁ + j₂, and the 2j + 1 states of those multiplets add up to the (2j₁ + 1)(2j₂ + 1) product states. Use the supplied topic model Y_out = j1+j2-min(p,floor(j1+j2)), where Y_out is SHADED COLUMN M (dimensionless). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793; min(a,b) selects the smaller value. j1 is First angular momentum j₁, dimensionless. Keep j2 (Second angular momentum j₂) = 1; p (Shaded column, steps below top) = 1 fixed. For this exercise use only 0 ≤ j1 ≤ 3, at the specified test settings separated by 0.5. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. Calculate Y_out at j1 = 0.5 and 1. Find the signed output change ΔY_out and the average sensitivity ΔY_out/Δj1 across this interval. State whether the response increases or decreases; explain why a finite difference between these settings does not require interpolation between them.

Explore the question data

SHADED COLUMN M against j1

Predictions from the supplied The allowed values of j, from |j₁ − j₂| to j₁ + j₂ model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.

Vertical axis (y): SHADED COLUMN M

SHADED COLUMN M against j1Predictions from the supplied The allowed values of j, from |j₁ − j₂| to j₁ + j₂ model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law. Horizontal axis: j1: First angular momentum j₁. Vertical axis: SHADED COLUMN M. Exact values are available in the data table below.-0.120.691.52.313.12-0.120.691.52.313.12xy

Horizontal axis (x): j1: First angular momentum j₁

Axes show the supplied calibration interval; the origin may lie outside the plot.

Reading 1j1: First angular momentum j₁: 0SHADED COLUMN M: 0
Read the exact data as a table
SHADED COLUMN M against j1 — supplied values
j1: First angular momentum j₁SHADED COLUMN M
00
11
1.51.5
2.52.5
33

These are the supplied values, not a worked answer. No fitted trend is drawn.

Show a hint

Substitute each value of j1 separately while keeping every other input fixed, then subtract in the same order.

Reveal the worked solution
  1. At j1 = 0.5, substitute into Y_out = j1+j2-min(p,floor(j1+j2)): Y₀ = 0.5.
  2. At j1 = 1, the same fixed-parameter model gives Y₁ = 1.
  3. Signed change: ΔY_out = Y₁ − Y₀ = 0.5; the input change is Δj1 = 0.5.
  4. Average sensitivity is ΔY_out/Δj1 = 1 1 per unit input. Its positive sign means that this response increases over the specified interval.
  5. This finite difference compares two specified test settings without interpolating between them. A point derivative is not required. Any quantum numbers or particle counts must also obey their physical admissibility conditions.

Answer Y₀ = 0.5, Y₁ = 1; ΔY_out = 0.5; average sensitivity = 1 1 per unit input.

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.

Extra challenging questions

Work through the linked stages and explain what each result means.

Extra challenging · 01

The allowed values of j, from |j₁ − j₂| to j₁ + j₂: infer an input with uncertainty

Coupling angular momenta j₁ and j₂ produces exactly one multiplet of total angular momentum j for each j = |j₁ − j₂|, |j₁ − j₂| + 1, …, j₁ + j₂, and the 2j + 1 states of those multiplets add up to the (2j₁ + 1)(2j₂ + 1) product states. Use the supplied topic model Y_out = j1+j2-min(p,floor(j1+j2)), where Y_out is SHADED COLUMN M (dimensionless). The output symbol Y_out is distinct from all input symbols. ^ denotes a power; π = 3.141592653589793; min(a,b) selects the smaller value. j1 is First angular momentum j₁, dimensionless. Keep j2 (Second angular momentum j₂) = 1; p (Shaded column, steps below top) = 1 fixed. For this exercise use only 0 ≤ j1 ≤ 3, at the specified test settings separated by 0.5. A grid of test settings is an input restriction for this exercise, not by itself a claim of physical quantisation. This calculation retains the topic model's stated assumptions; it does not extend them to a different physical setup. A reading gives Y_out = 2, with a bounded reading uncertainty ±0.24. Treat the model and all fixed inputs as exact for this exercise; the bound is not a standard deviation. Determine every allowed value of j1 consistent with that bound. Compare with a straight-line interpolation between the two endpoint predictions, and explain why a fractional setting may be inadmissible. Do not assume that the supplied calibration points prove monotonicity outside this branch.

Explore the question data

SHADED COLUMN M against j1

Predictions from the supplied The allowed values of j, from |j₁ − j₂| to j₁ + j₂ model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law.

Vertical axis (y): SHADED COLUMN M

SHADED COLUMN M against j1Predictions from the supplied The allowed values of j, from |j₁ − j₂| to j₁ + j₂ model, with all other inputs fixed as stated in the question. 5 calibration points support a trend comparison; they are not measured data or a straight-line law. Horizontal axis: j1: First angular momentum j₁. Vertical axis: SHADED COLUMN M. Exact values are available in the data table below.-0.120.691.52.313.12-0.120.691.52.313.12xy

Horizontal axis (x): j1: First angular momentum j₁

Axes show the supplied calibration interval; the origin may lie outside the plot.

Reading 1j1: First angular momentum j₁: 0SHADED COLUMN M: 0
Read the exact data as a table
SHADED COLUMN M against j1 — supplied values
j1: First angular momentum j₁SHADED COLUMN M
00
11
1.51.5
2.52.5
33

These are the supplied values, not a worked answer. No fitted trend is drawn.

Show a hint

Enumerate the permitted settings in the stated range, evaluate Y_out at each, and retain every setting satisfying |Y_out − Y_measured| ≤ u. The plotted predictions are supplied calibration evidence.

Reveal the worked solution
  1. Endpoint predictions are Y_out(0) = 0 and Y_out(3) = 3. The target lies between them. On the selected branch the response is strictly increasing.
  2. Endpoint interpolation gives j1_line = 0 + (2 − 0)(3 − 0)/(3 − 0) = 2. This estimates the inverse of the endpoint chord, rather than assuming that chord is the physical model.
  3. Evaluate the model at each permitted setting. The central reading corresponds to j1 = 2; only the allowed settings 2 lie inside the stated reading bound.
  4. The interpolation error in the input is |j1_line − j1| = 0.
  5. The compatible allowed values span 2 to 2. Values between specified test settings are outside this exercise's input domain even if an interpolation passes through them.
  6. The quoted output bound restricts which specified settings remain compatible. It does not change physical restrictions on quantum numbers or counts, and the chosen grid alone does not establish physical quantisation.

Answer Compatible j1: 2. Endpoint interpolation predicts 2; check admissibility against the discrete settings.

Compare the assumptions, method and units with your attempt. Explain any correction before trying another question.